China World Technology Medical Equipment Service Group
                                                                                                           
Verified Supplier
11 Years
Since 2015
Menu

AAMI REF 989803129231 Alligator Clips AAMI Bag Of 10 1/8" Post For Tab Electrodes

Price Negotiable
Price: Negotiable
MOQ: 1
Delivery Time: 3-5 working days
Brand: PHiliph
Product Description

 

PHiliphh Alligator Clips,AAMI REF 989803129231 Alligator Clips AAMI (Bag of 10) 1/8" post., for tab electrodes

 

 

 

► Brief Introduction

Acquisition of quality ECG data is critical in providing accurate and timely diagnosis and patient treatment. Poor ECG quality can:

  • result in the monitor’s inability to recognize the R-wave, thus affecting arrhythmia analysis and the ability to perform procedures such as synchronized cardioversion and transcutaneous pacing,
  • inhibit reading a 12-Lead accurately, and
  • result in false alarms and unnecessary troubleshooting, potentially delaying treatme

 

► Lead Selection

It is important to select a suitable lead that shows the largest amplitude and cleanest signal so that a QRS complex and R-wave, in particular, can be accurately detected by the monitor. Consider the following lead selection guidelines:

  • The QRS complex should be tall and narrow (recommended amplitude > 0.5 mV).
  • The R-wave should be above or below the baseline (but not biphasic).
  • The P-wave should be smaller than (1/5) R-wave height.
  • The T-wave should be smaller than (1/3) R-wave height.

To prevent detection of P-waves or baseline noises as QRS complexes, the minimum detection level for QRS complexes is set at 0.15 mV, according to AAMI-EC 13 specifications. If the ECG signal is too weak, you may get false alarms for asystole.In many monitors, increasing the gain (size) of the ECG does not change the signal to the monitor. Therefore, the signal should meet the above criteria without changing the gain to ensure the monitor can accurately analyze the waveform.

 

 

► Specifications

 

Product Category ECG
Use with Non-PHiliphh Healthcare Equipment No
Single-Patient Use OR Multi-Patient Use Multi-Patient Use
Not manufactured with natural rubber latex Yes
Packaging Unit 10 adapters
Minimum Shelf Life None
Sterile OR Non-Sterile Non-Sterile
Use with PHiliphh Healthcare Equipment 860284, 860286, 860287, 860288, 860290, 860297, 860284, 860300, 860310, 860315

 

 

 

 

 

► About Us

CWT Technology HK Limited, located in Guangzhou, China. During these years of marketing and expansion, we have accumulated a great wealth of experience in both product distribution and customer service. We are a trustworthy medical equipment supplier where we have been involved in the industry for many years. The customer will receive satisfactory goods.
I have supply the medical equipment and parts of Patient Monitor, Defibrillator Machine, ECG Machine,Ultrasound such as
GE,
PHiliphhilip,
Mindray,
Goldway,
Nihon Kohden,
Med-tronic,
Drager,
Edan,
Zoll,
etc.,
We understand the importance of the concept of win-win cooperation, are committed to protecting the medical equipment market, and meeting all customer requests is our constant pursuit.

 

 

 

 

Thank you for your time! If you are interested in PHiliphh Alligator Clips,AAMI REF 989803129231 Alligator Clips AAMI (Bag of 10) 1/8" post., for tab electrodes , welcome to place your orders. Early order early shipment! Looking forward to receiving your early inquiry.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company China World Technology Medical Equipment Service Group
Location TianHe District,GuangZhou,GuangDong
Contact Person Kiara

Request A Quote

Please check your email address.
Your message must be at least 20 characters.