PHiliph MX40 Patient Monitor parts Spo2 Parameter Board M1020-66434

Price Negotiable
Price: Negotiable
MOQ: 1pcs
Delivery Time: 3-5 working days
Brand: PHiliph
Product Description

PHiliphh MX40 Patient Monitor Spo2 Board M1020-66434

 

 

FAST SpO2

Parameter Specification
SpO2 Measurement Range (Calibration and Display) 0 to 100%
SpO2 Accuracy See table following
SpO2 Resolution 1%
SpO2 Numerics - Averaging 5 - 20 seconds (default = 10 seconds) Note – SpO2 pulse oximetry and pulse rate are normally updated at 1 second intervals. This can be expanded as much as possible. After 60 seconds, when NIBP is measured in the same limb, the corresponding INOP message is displayed after the maximum. for 30 seconds to indicate that the displayed value is not the current value. The effect of SpO2 on average pulse oximeter data can be monitored internally by the MX40 patient-worn monitor and no user control is required.
SpO2 & Pulse Numerics - Update Rate Sent once per second. Note - SpO2 pulse oximetry readings and pulse update rates are typically 1 second. This can be extended as much as possible. 60 seconds when NIBP is measured at the same point, corresponding message INOP max 30 seconds to indicate that the displayed value is not current.
Pleth Wave- Sampling Rate 125 sps
Technical Alarms (INOPs) Activated when the sensor is disconnected, no pulse, noisy signal, detected light interference, sensor failure, measurement instability or module failure.
Wavelength Range 500-1000 nm Note – Information about this wavelength range may be particularly useful for physicians (eg, physicians performing photodynamic therapy).
Pulse Rate Measurement (available only with Continuous SpO2) Range: 30 to 300 bpm Accuracy: +/- 2% Resolution: 1 bpm
Display of SpO2 numerics SpO2 values are displayed as xxx % SpO2 to meet ISO 9919.
Emitted Light Energy < =15 mW

 

 

Company introduction

 

CWT Technology HK Limited prides itself on the quality and consistency of the products and services we provide to our customers. Our website has many options such as cables, batteries, motherboards, screens, touch screens, modules, keyboards, sensors, power sensors, etc. With many years of direct contact with customers and professional engineers with more than 12 years of experience, we always we show our craft because you feel better when you shop.

 

All orders are carefully processed as needed. We are very grateful for your purchase. Our customers always expect and receive quality products when they place orders with us. Our goal is to offer our customers the right product at the right price with fast delivery.

 

We have a strong customer service team that will take care of the entire sales process. Our team is always ready to help you with returns and exchanges and listen to your complaints. Our service team follows his instructions.

 

If you're interested in M1020-66434 PHiliphh MX40 Patient Monitor Spo2 Parameter Board,feel free to contact us .Thank you .

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company China World Technology Medical Equipment Service Group
Location TianHe District,GuangZhou,GuangDong
Contact Person Kiara

Request A Quote

Please check your email address.
Your message must be at least 20 characters.