China World Technology Medical Equipment Service Group
                                                                                                           
Verified Supplier
11 Years
Since 2015
Menu
Service Equipment Restaurant & Hotel Supplies Other Hotel & Restaurant Supplies

NIBP Pump Patient Monitor parts 02.01.210749 Hospital Equipment Parts

Price Negotiable
Price: Negotiable
MOQ: 1
Delivery Time: 3-5 working days
Brand: Edan
Product Description

Edan IM60 Patient Monitor NIBP Pump 02.01.210749

Edan IM60 Patient Monitor NIBP Pump 02.01.210749 Hospital Equipment Parts In Good Working Condition

 

 

► Brief Introduction

This monitor uses the oscillometric method to measure NIBP. It can be used for adult, pediatric and neonatal patients.

Oscillometric devices measure the amplitude of pressure changes in the occluding cuff as the cuff is deflated above systolic pressure. The amplitude increases suddenly as the pulse traverses the occlusion of the artery. As the cuff pressure decreases further, the pulsations increase in amplitude, reach a maximum (approximately the mean pressure), and then decrease.

 

In adult and pediatric mode, blood pressure measurements determined with this device comply with the American National Standard for Electronic or Automated Sphygmomanometers (ANSI/AAMI SP10-1992) for mean error and standard deviation, compared to measurements auscultatory in a representative. patient population. For auscultatory reference, the fifth Korotkoff sound was used to determine diastolic pressure.

 

In neonatal mode, blood pressure measurements determined with this device meet the American National Standard for Automated or Electronic Sphygmomanometers (ANSI/AAMI SP10-1992) for mean error and standard deviation, compared to intra-arterial measurements in a rep. patient population.

 

 

 

Measurement Limitations

Measurements are impossible with heart rate extremes of less than 40 bpm or greater than 240 bpm, or if the patient is on a heart-lung machine.

The measurement may be inaccurate or impossible in the following situations:

  • A regular arterial pressure pulse is hard to detect.
  • Patients with cardiac arrhythmias.
  • Patients with excessive and continuous movement such as shivering or convulsions.
  • Patients with rapid blood pressure changes.
  • Patients with severe shock or hypothermia that reduces blood flow to the peripheries.
  • Patients with obesity, where a thick layer of fat surrounding a limb dampens the oscillations coming from the artery.
  • Patients on an edematous extremity.

 

 

Measurement Range

Adult mode SYS: 40 mmHg ~ 270 mmHg
DIA: 10 mmHg ~ 215 mmHg
MAP: 20 mmHg ~ 235 mmHg
Pediatric mode SYS: 40 mmHg ~ 200 mmHg
DIA: 10 mmHg ~ 150 mmHg
MAP: 20 mmHg ~ 165 mmHg
Neonatal mode SYS: 40 mmHg ~ 135 mmHg
DIA: 10 mmHg ~ 100 mmHg
MAP: 20 mmHg ~ 110 mmHg

 

 

 

 

About Company

We have years of proven service experience in manufacturing and selling medical apparatus and instruments. Our products are all of high quality and always have won high praise from the customers at home and abroad.

Here at CWT Technology HK Limited, we offer a wide range of quality medical equipments, accessories and repair parts including patient monitor, defibrillator machine, patient monitor printer, ECG machine, EKG machine, that is specific to your clinical capabilities and fit your needs and budget, with the quality and reliability that you would expect.

 

 

 

Please kindly contact us, if you are interested in Edan IM60 Patient Monitor NIBP Pump 02.01.210749 , Thank you!

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company China World Technology Medical Equipment Service Group
Location TianHe District,GuangZhou,GuangDong
Contact Person Kiara

Request A Quote

Please check your email address.
Your message must be at least 20 characters.