GE Invasive Pressure IP Adapter Cable IBP Tram 451 Dual Adaptor 0.3 Meter REF 2005772-001

Price Negotiable
Price: Negotiable
MOQ: 1
Delivery Time: 3-5 working days
Brand: GE IP Adapter cable
Product Description

 

GE Invasive Pressure IP Adapter cable IBP Tram 451 Dual Adaptor 0.3 Meter REF 2005772-001

 

 

► Brief Introduction

The dual invasive blood pressure adapter is intended to be used for connection two invasive blood pressure transducers to GE Medical System Information.

Work for GE B20 B20i B40 B105 B125 Modules. Cath-Lab, MAC-Lab, Dash 1000, Dash 2000, Dash 3000, Dash 3100, Dash 4000, Dash 5000, Eagle, Solar 7000, Solar 8000, Solar 9000, Tram 451, Tram Module 100-600, Tram Rac 3, Tram Rac 4A, Tram Scope 100-800 A, Tram Scope 100-800 L

To measure invasive blood pressure, a catheter is inserted into an artery or vein. The invasive pressure setup, consisting of a connecting tubing, a pressure transducer, an intravenous bag of normal saline, all connected together by stopcocks, is attached to the catheter. The transducer is placed at the same level with the heart, and is electrically zeroed.

The transducer is a piezo-resistive device that converts the pressure signal to a voltage. The monitor interprets the voltage signal so that pressure data and pressure waveforms can be displayed.

 

 

Invasive blood pressure measurement

Configure the simulator’s IBP channels as follows:

Sensitivity: 5 µV/V/mmHg

InvBP outputs: "0 mmHg static pressure" or "atmosphere"

  • Zeroing
  • Press IBP Zero All key.
  • Check that a message "Zeroing" followed by a message "Zeroed" is shown in the IBP parameter window.
  • Static Pressure
  • Configure the simulator's InvBP output to "200 mmHg static pressure".
  • Check that the flat pressure line appears on the related waveform field. The reading in the parameter window shall be 200 ±10 mmHg.

NOTE: Recalibration is required, if the measured value is not within the specification.

  • Pressure Waveforms
  • Configure the simulator's InvBP output to "Arterial 120/80".
  • Check that the pressure waveform for tested invasive pressure channel appears in the IBP waveform field and the Sys/Dia (Mean) pressure values are shown in the related parameter window.

 

 

► Invasive blood pressure connectors (IBP1, IBP2)

1 BP_+VREF BP transducer excitation voltage, channel 1
2 BP SIG+ BP transducer signal positive (+), channel 1
3 BP_+VREF BP transducer excitation voltage, channel 2
4 AGND Analog ground
5 BP SIG+ BP transducer signal positive (+), channel 2
6 SHIELD BP cable shield
7 AGND Analog ground
8 BP SIG1 BP transducer signal negative (-), channel 1
9 BP SIG2 BP transducer signal negative (-), channel 2
10 BP1_ID BP1 probe identification
11 NC Not connected

 

 

 

If you have other inquiry of GE Invasive Pressure IP Adapter cable IBP Tram 451 Dual Adaptor 0.3 Meter REF 2005772-001, please feel free to contact us.

We are always ready to serve you.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company China World Technology Medical Equipment Service Group
Location TianHe District,GuangZhou,GuangDong
Contact Person Kiara

Request A Quote

Please check your email address.
Your message must be at least 20 characters.