Dash3000 Dash4000 Dash5000 Patient Monitor Parts Power Supply Board 801394-001
GE Dash3000 Dash4000 Dash5000 Power Supply Board
GE Dash3000 Dash4000 Dash5000 Patient Monitor Power Supply Board 801394-001
► Brief Description
GE Dash3000 Dash4000 Dash5000 Patient Monitor Power Supply Board 801394-001 is the main power source of GE Dash3000 Dash4000 Dash5000 Patient Monitor. It is a power conversion power supply. Its main function is to convert standard AC power into low-voltage stable DC power, or directly convert DC power into low-voltage stable DC power for GE Dash series patient monitors. It supplies the power of the entire device, and without it, these monitor devices will not be able to operate due to lack of power. Although GE Dash3000 Dash4000 Dash5000 Patient Monitor can be powered not only by wired connection, but also by battery. But they all need to go through the power supply board to reach GE Dash3000 Dash4000 Dash5000 Patient Monitor equipment. So it's one of the most important parts of the whole device.
► Specifications
| 90-132VAC | 50/60 Hz 2.0A |
| 190-264 VAC | ±20 MV (max) |
| CONDITION | In Good Working Order |
| FUNCTIONALITY | Power Supply Board |
| TRANSPORTATION | Express |
| Brand | GE |
| Warranty | 90 Days |
| Part Number | 801394-001 |
► Function
The main function of the GE Dash3000 Dash4000 Dash5000 Patient Monitor Power Supply Board 801394-001 is to convert the AC power obtained from the wall socket into a low-voltage DC power that can be used by electronic equipment. Since different components in the GE Dash series patient monitors require different voltages and all require stable and continuous DC voltages, the Power Supply can provide several DC voltages; in addition, the Power Supply must be equipped with a voltage regulator/stabilizer Regulator (voltage regulator) to provide accurate and stable voltage value to ensure the normal operation of various components in the patient monitor.
► Replace power supply assembly
1. Holding the power supply assembly with one hand, remove the four screws from the back of the unit
2. Remove components from equipment.
3. Align the tabs on the power supply mounting bracket with the slots on the rear case and install the new assembly into the unit. Secure the assembly to the rear case with new screws.
NOTE: When attaching the thumbscrews to the writer flex, first tighten the thumbscrews by hand. Then, use a flathead screwdriver to tighten the screw an additional 1/4 turn.