COMEN C60 Patient Monitor Parts ECG Connector For Hospital Medical Equipment
Hospital Medical Equipment COMEN C60 Patient Monitor ECG Connector in stock with good working condition
COMEN C60 Patient Monitor ECG Connector
► Brief Introduction
ECG monitoring describes continuous waveforms of cardiac activities of patients so as to accurately assess the current psychological status of the patients. Thus proper connection of ECG cables must be ensured in order to obtain correct measurement values. This portable monitor concurrently can display 2 waveforms under normal work status.
A patient cable consists of two parts: Wire connecting the monitor; Leads connecting patients With a 3-lead facility for monitoring, ECG can obtain two waveforms from two different leads.Displayed monitoring parameters include HR, ST segment measurement value and arrhythmia.
► Connect ECG Cable
1) First install the spring clip before placing the electrode.
2) Place the electrode on the patient’s body; if the electrode used does not contain conductive paste, please apply conductive paste prior to placement.
3) Connect the electrode leads with the patient cable.
4) Insert the patient cable into the ECG port on the monitor. The monitor shows the ECG wave and value
► Features
- According to the character of neonate’s HR, use the latest COMEN TM ExNeo ECG Technology to guarantee the accuracy of measurement.
- Anti-motion respiration testing technology, apnea alarm
- Specialized neonatal ECG cable and electrodes
► Precautions for ECG Monitoring
- Prior to monitoring, please test the sensor cable to see if it is normal. When the ECG cable is disconnected from the jack, the screen will display the prompt message “ECG Lead Off” and generate the alarm sound.
- When this monitor is used for ECG signal monitoring, ECG leads provided by Comen must be used.
- When connecting the electrodes or patient cable, please ensure that the patient does not come into contact with any other conductive parts or the ground. Especially, please confirm that all ECG electrodes (including neutral electrode) are attached onto the patient’s body and will not come into contact with any conductive parts or the ground.
- Check whether the ECG electrode patch can irritate skin every day. If there is any sign of allergy, replace the electrode or change its position.
- Prior to ECG monitoring, please check the ECG cable. When the ECG cable is disconnected, the monitor will trigger a sound alarm and display the alarm message “Sensor Off”.
► Specification
| Lead Type | 5 lead and 3 lead selectable |
| 5 leadwire cable | RA; LA; RL; LL; V or R; L; N; F; C |
| 3 leadwire cable | RA; LA; LL or R; L; F |
| Lead Selection | 5-lead: I; II; III; aVR; aVL 3-lead: I; II; III |
| Gain Selection | x0.25, x0.5, x1, x2, x4, auto |
| Sweep Speed | 6.25, 12.5, 25, 50mm/s |
| Heart Rate Range | Pediatric/Neonate: 15-350bpm |
| Resolution | 1 bpm ±1% or ±2bpm |
| Filter | MON: 0.5-40Hz DIA: 0.05-130Hz OPE: 1-20Hz |
| ST Segment | -2.0mV - +2.0Mv |
| Detection Arrhythmia | Yes |
Please kindly contact us, if you are interested in COMEN C60 Patient Monitor ECG Connector , Thank you!