1.4 lb Patient Monitor Module GE Datex Ohmeda E-PSMPW Carescape Patient Side Module

Price Negotiable
Price: Negotiable
MOQ: 1pcs
Delivery Time: 3-5 working days
Brand: GE
Product Description

GE Datex Ohmeda E-PSMPW Carescape Patient Side Module

 

 

 

Specification

Module size (W x D x H) 55 x 135 (175 w/ tab) x 145 mm (2.2 x 5.3 (6.9 w/ tab) x 5.7 in)
Module weight 0.6 kg /1.4 lb
Operation temperature 5 to 40°C / 41 to 104°F

 

 

 

NIBP

 

NOTE: Non-invasive blood pressure measurement is intended for patients weighing over 5 kg

Measurement range
adult 25 to 260 mmHg
child 25 to 190 mmHg
infant 15 to 140 mmHg
Pulse rate range accepted 30 to 250 bpm
Typical measuring time
adult < 30 s
infant < 25 s
Inflation limit
adult 280 ±10 mmHg
child 200 ±10 mmHg
infant 150 ±5 mmHg
Venous stasis
adult 80 ±5 mmHg / 2 min
child 60 ±5 mmHg / 2 min
infant 40 ±5 mmHg / 1 min.

 

 

 

ECG

Lead type

3-Lead (I, II, III)

5-Lead (I, II, III, aVR, aVL, aVF, V)

 

Sweep speeds 12.5, 25, 50 mm/sec.
Defibrillation protection 5000 V, 360 J
Recovery time 5 s
Input impedance >2.5 MΩ (10 Hz)
Allowable offset ±1VDC
Gain range 0.2 to 5.0 cm/mV

 

 

Pulse oximetry

 

Measurement range 0 to 100%
Calibration range 70 to 100%
Pulse rate from Pleth
Measurement range 30 to 250 bpm
Accuracy ±5 bpm or ±5%, whichever is greater
Resolution 1 bpm
Display averaging 5-20 s

 

 

 

 

Temperature

Measurement range 10 to 45 °C (50 to 113 °F)
Measurement accuracy ±0.1 °C
Display resolution 0.1 °C at 25-45 °C with reusable probes
Temperature test automatic (every 10 min.)
Probe type compatible with YSI 400 series

 

Invasive blood pressure

 

Measurement range -40 to 320 mmHg
Measurement accuracy ±5% or ±2 mmHg, whichever is greater
Zero adjustment range ±150 mmHg
Zero time less than 15 s
Transducer sensitivity 5 µV/V/mmHg

 

Respiration

 

Measurement range 4 to 120 breath/min
Accuracy ±5 breath/min or ±5%, whichever is greater
Resolution 1 breath/min
Gain range 0.1 to 5cm/ohm

 

 

Patient Side Module E-PSMPW

 

 

(1) Module keys

  • NIBP connector
  • Invasive blood pressure connector: 2-channel measurement
  • Temperature connector: 2-channel measurement
  • SpO2 connector
  • ECG (3/5 lead) and impedance respiration connector
  • Tab for removing the module

 

 

 

Module keys

The E-PSM(P)W modules have the following direct function keys:

 

For starting or stopping the NIBP automatic cycling.

 

For starting or stopping the NIBP manual cycling.

For zeroing pressure channel P1 NOTE: with E-PSMPW only.

 

For zeroing pressure channel P2 NOTE: with E-PSMPW only.

 

 

 

Thank you  for your attention .If you're interested in GE Datex Ohmeda E-PSMPW Carescape Patient Side Module,feel free to contact us .Thank you .

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company China World Technology Medical Equipment Service Group
Location TianHe District,GuangZhou,GuangDong
Contact Person Kiara

Request A Quote

Please check your email address.
Your message must be at least 20 characters.