Edan IM50 Patient Monitor Parts Parameter Panel Board Spare Parts

Price Negotiable
Price: Negotiable
MOQ: 1pcs
Delivery Time: 3-5 working days
Brand: Edan
Product Description

Edan IM50 patient monitor parameter panel board brief introduction

 

Edan IM50 patient monitor parameter panel board is part of the patient monitoring system that displays various parameters related to the patient's vital signs. This panel typically displays information such as heart rate, blood pressure, oxygen saturation, respiratory rate, temperature, and ECG waveforms. It allows healthcare professionals to monitor a patient's condition in real time and intervene as necessary. Panels can also allow alerts to be set when certain values fall outside normal ranges, enabling healthcare professionals to quickly respond to potential problems. Overall, a patient monitor parameter panel is an essential part of a patient monitoring system that ensures continuous monitoring and maintenance of patient safety and health.

 

 

 

Product Name

Edan IM50 patient monitor parameter panel board

 

Brand Edan
Use for Edan IM50 patient monitor
Material Plastic
Condition Used
Warranty 90 days
MOQ One piece

 

 

Parameter Monitoring Failures

Phenomenon Possible Cause Solution
No ECG waveform Bad connection of ECG cable. Check the connection of the ECG cable.
The ECG cable is damaged Replace the ECG cable
Bad connection of the electrodes. Check the connection
Circuit failure of ECG on the main control board. Replace the main control board
No SpO2 trace or measurements. SpO2 sensor failure Replace the SpO2 sensor
Bad connection of the cable of the SpO2 sensor Check the connection
Circuit failure of SpO2 on the main control board. Replace the main control board
The cuff fails to be inflated Bad connection of the cuff, the pump and the NIBP connector Check the connection outside the monitor
Bad connection of BP module and NIBP connector Check the connection inside the monitor.
The cuff or the extended cable is damaged Replace the damaged parts
Circuit failure of BP on the main control board Replace the main control board
NIBP cuff pressure value has no obvious change. Circuit failure of BP on the main control board. Replace the main control board.
NIBP tube leakage Please perform leakage test and change the tube or valve.
No NIBP measurement values or no alarm information Cuff or extension tube abnormal Please replace the cuff or extension tube.
Circuit failure of BP on the main control board. Replace the main control board
No TEMP measurement value. TEMP sensor failure. Replace the TEMP sensor
Bad connection of TEMP sensors. Check the connection
Circuit failure of TEMP on the main control board Replace the main control board.

 

 

 

 

Thank you so much for your attention .If you're interested in Edan IM50 Patient Monitor Parameter Panel Board Spare Parts ,feel free to contact us .Thank you .

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company China World Technology Medical Equipment Service Group
Location TianHe District,GuangZhou,GuangDong
Contact Person Kiara

Request A Quote

Please check your email address.
Your message must be at least 20 characters.