Mindray MOX-4 Oxygen Sensor Cable 122009708

 

 

About Mindray MOX-4 Oxygen Sensor Cable 122009708

 

The Mindray MOX-4 Oxygen Sensor Cable is a replacement cable used with the Mindray MOX-4 oxygen sensor. This cable is designed to

 

provide a reliable connection between the sensor and the monitoring device, ensuring accurate and consistent oxygen level readings. It is an

 

 

essential component for patient monitoring in hospital settings and healthcare facilities.

 

 

Specification of Mindray MOX-4 Oxygen Sensor

 

MEASUREMENT
Operating Principle Partial pressure electrochemical
Output 9 mV to 13 mV in 210 mBar O2
Measurement Range 0 mBar to 1500 mBar O2
Baseline Offset <200 μV
ENVIRONMENTAL
Typical Applications Critical care anesthesia
Operating Temperature Range Range -20°C to +50°C
Operating Pressure Range 0.5 Bar to 2.0 Bar
Operating Humidity Range 0% to 99% RH noncondensing

 

 

 

Purpose of use

These sensors are designed for oxygen partial pressure monitoring in anesthesia (except xenon), intensive care, neonatal incubators and general

 

oxygen monitors.

 

 

 

Stabilization time.

 

Wait at least 15 minutes for the instrument to stabilize before calibrating or refer to the manufacturer's instructions.

 

 

 

Cleaning and sterilization

 

If the sensor is dirty, clean it with distilled water and allow it to air dry. This sensor is not suitable for steam sterilization or exposure to chemicals

 

such as ethylene oxide or hydrogen peroxide.

 

 

 

Calibration interval

 

If the sensor is dirty, clean it with distilled water and allow it to air dry. This sensor is not suitable for steam sterilization or exposure to chemicals

 

such as ethylene oxide or hydrogen peroxide.

 

 

 

If you drop the sensor

 

If a sensor is dropped, it must be isolated for 24 hours and then a two-point calibration performed.

 

 

mechanical installation

 

When installing the sensor, simply screw it in tightly by hand to ensure a tight seal. Do not use wrenches or similar mechanical devices as

 

excessive force may damage the sensor threads.

 

 

Photos 

 

Below picture is Mindray City MOX-4 MOX4 O2 Oxygen Sensor Cable 122009708 New .The cable condition is new .

 

 

 

 

About us

 

CWT Technology HK Limited is a developing company ,mainly selling patient monitor ,ECG ,defibrillator ,ultrasound ,spare parts ,accessories

 

.With the developing ,our customers are from all over the world,such as USA ,Italy ,Spain ,Malaysia ,PHiliphhpines,Indonesia ,Thailand ,Colombia

 

,Saudi Arabic ,United Arab Emirates ,Oman etc .

 

 

Thank you so much for your attention .If you're interested in Mindray MOX-4 MOX4 O2 Oxygen Sensor Cable 122009708 ,feel free to contact us .Thank you .

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company China World Technology Medical Equipment Service Group
Location TianHe District,GuangZhou,GuangDong
Contact Person Kiara

Request A Quote

Please check your email address.
Your message must be at least 20 characters.