Edan Reusable NIBP Cuff E8 Small Adult 20.5 - 28 Cm New Original NIBP Blood Pressure Cuff For Edan Monitor
Edan Reusable NIBP Cuff E8 Small Adult 20.5 - 28 cm New Original NIBP Blood Pressure Cuff for Edan Monitor
► Brief Description
• Before use, make sure the cuff, cuff tube, and hose are clean and in good condition. Do not inflate the cuff if it is old, cracked, or not sealing. Do not use if the cuff is structurally damaged or damaged.
• Palpate the artery and position the cuff so that the patient's artery is aligned with the arrow labeled "Artery" on the cuff.
• Check the patient's limb before use. Do not place the cuff over any area of damaged skin or tissue. The hooks may cause irritation if they touch the skin.
• Wrap the cuff securely around the patient's limb. If using the upper arm, make sure the hook-and-loop fastener is properly engaged so that pressure is evenly distributed around the cuff. , position the cuff as close together as possible.
► Specification
| Brand name | Edan |
| Model Number | E8 |
| Product Name | Edan Reusable NIBP Cuff |
| Color | Brown |
| MOQ | 1 Piece |
| Condition | New and Original |
| Application | Medical Equipment,ICU,Hospital Device |
| Method of Transport | Expressage |
| Type | Spare Part |
| Payment Terms | Full Before Shipment |
| Packing | Carton |
| Warranty | 90 Days |
| Delivery | 3-5 Waking Days |
| Languages: | Multi-lingual Support |
Instructions for Use
• If the patient is standing, sitting, or lying, make sure the cuff is supported so that it is at the same level as the patient's heart. If the cuff is not at heart level, the difference in systolic and diastolic blood pressure measurements due to hydrostatic pressure effects must be considered.
• Select the appropriate cuff size. Measure the patient's limbs and select the appropriate cuff size based on the size listed on the cuff or cuff packaging. If the cuff size overlaps the specified circumference, select a larger cuff size. Accuracy is determined by using the correct cuff size.
• Deflate the cuff and ensure that the cuff is connected to a non-invasive blood pressure monitor. Make sure the connection is secure and the hose is not kinked.
• Select the appropriate blood pressure measurement site. For convenience, the upper arm is recommended because reference values are generally based on this side. When using the upper arm, the appropriate cuff should be selected considering the patient's cardiovascular condition, the effect of alternate sites on blood pressure readings, and the appropriate cuff size and comfort.
• Proper cuff wrapping should fit tightly but still allow room for a finger between the patient and the cuff. The cuff should not be tight enough to prevent venous return between provisions.