China World Technology Medical Equipment Service Group
                                                                                                           
Verified Supplier
11 Years
Since 2015
Menu

11101-000016 Physio-Control Infant Child Reduced Energy Defibrillation Electrodes for LIFEPAK 1000 Defibrillator

Price Negotiable
Price: Negotiable
MOQ: One piece
Delivery Time: 3-5 working days
Brand: Physio-Control
Product Description

Physio-Control Infant Child Reduced Energy Defibrillation Electrodes 11101-000016 for LIFEPAK 1000 Defibrillator

 

 

About LIFEPAK 1000 Defibrillator

 

MODES OF OPERATION

 

You can use the LIFEPAK 1000 defibrillator for:

• Automated external defibrillation (AED mode)

• Manual defibrillation therapy (Manual mode) (Requires ECG display option)

• ECG monitoring (ECG mode) (Requires ECG display option)

 

 

 

Basic steps for using the LIFEPAK 1000 defibrillator

 

1 Make sure the patient is in cardiopulmonary arrest (the patient should be unresponsive, not breathing normally, and showing no signs of circulation).

2 Press ON/OFF to turn on the defibrillator (the green LED will be on). You will hear voice prompts to guide you through the save process.

3 Prepare the patient for therapeutic electrode placement.

• If possible, lay the patient on a hard surface away from standing water. • Remove clothing from the patient's upper body.

• Remove excess hair from the electrode sites. If shaving is necessary, avoid cutting the skin.

• Clean the skin and dry it vigorously with a towel or gauze.

• Do not apply alcohol, benzoin, or antiperspirants to your skin.

 

4 Open the therapy electrode package and remove the electrodes. Slowly remove the protective sheath from the electrodes, starting at the connector end of the cable. Discard the liner safely to prevent slippage.

 

5 Place the therapy electrodes on the patient's chest. Starting at one end, press the electrodes firmly into the patient's skin as shown.

 

 

6 Connect the electrodes to the defibrillator (if they are not already connected).

7 Follow the screen messages and voice prompts provided by the defibrillator.

 

 

With Infant/Child pads:

 

The following specifications apply from 25 to 175 ohms.

Energy Accuracy (into 50 ohms): Selected energy ¸ 4 +/- 15%;

86 joules +/- 15% maximum Rated energy output is the nominal delivered energy based on the energy setting and patient impedance, as defined in the following chart.

 

 

 

 

Specification of Physio-Control Infant Child Reduced Energy Defibrillation Electrodes 11101-000016 for LIFEPAK 1000 Defibrillator

 

Product Name Physio-Control Infant Child Reduced Energy Defibrillation Electrodes 11101-000016 for LIFEPAK 1000 Defibrillator
Brand Physio-Control
Part No 11101-000016
MOQ One piece
Warranty 90 days
Use for Lifepak 1000 defibrillator

 

 FAQ

 

1. How to promptly address quality issues arising during long-term cooperation?

The agreement shall specify a rapid response mechanism and compensation standards for quality issues.

 

2. Is there a trial discount for first-time collaborations?

First-time collaborations can apply for sample discounts or first-order shipping fee waivers.

 

3. Is a paper instruction manual included in the accessory packaging?

Each order batch comes with a paper version of the instruction manual; however, it may be omitted upon request to reduce packaging volume.

 

4. Do customers need to provide an import license for export accessories?

Generally not required, but for certain special accessories, customers need to assist in verifying local regulatory requirements.

 

5. How frequently is the instruction manual updated?

The manual is updated simultaneously with product upgrades, and the old version will be marked with the version number and update date.

 

Thank you so much for your attention .If you're interested in 11101-000016 Physio-Control Infant Child Reduced Energy Defibrillation Electrodes for LIFEPAK 1000 Defibrillator,feel free to contact us .Thank you .

 


90 Day Warranty                             SGS ceryification

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company China World Technology Medical Equipment Service Group
Location TianHe District,GuangZhou,GuangDong
Contact Person Kiara

Request A Quote

Please check your email address.
Your message must be at least 20 characters.