China World Technology Medical Equipment Service Group
                                                                                                           
Verified Supplier
11 Years
Since 2015
Menu

Edan F6 Fetal Maternal Monitor TOCO US Connector Interface Assembly 21.53.451265-1.0

Price Negotiable
Price: USD
MOQ: 1 Piece
Delivery Time: 3-5 working days
Brand: Edan
Product Description

TOCO & US Connector for Edan F6

Edan F6 Fetal & Maternal Monitor TOCO & US Connector Interface Assembly 21.53.451265-1.0 used

 

Brief Description

Edan F6 Fetal & Maternal Monitor TOCO & US Connector Interface Assembly is an important part of the monitor, which mainly connects the relevant probes with the monitor host and transmits signals.

1. TOCO refers to the connection interface of the uterine contraction pressure probe. The uterine contraction pressure probe is used to monitor the pressure changes caused by uterine contraction. When the uterus contracts, the pressure in the uterus will increase. The probe can monitor this pressure change and convert it into an electrical signal, which is transmitted to the monitor host through the connection interface.

2. The US interface is mainly used to connect the ultrasonic fetal heart probe. The ultrasonic probe can transmit and receive ultrasonic waves to detect the fetal heartbeat and other information. The interface transmits the fetal heartbeat signal collected by the ultrasonic probe to the monitor host, so as to display and monitor the fetal heart rate and other physiological indicators in real time.

 

 

TOCO & US

Accessories should be connected to the monitor via the sockets on the left side panel. Each accessory has a tab on the connector housing to ensure proper insertion into the corresponding socket on the monitor.

1. Ultrasound (US) Transducers

1. US Transducer Sensor (Pink Labeled)
2. Transducer Cable
3. Transducer Connector
 

2. TOCO Transducers

1. TOCOS Transducer Sensor (Blue Labeled)
2. Transducer Cable
3. Transducer Connector

 

 

► Replace

Replace the Edan F6 Fetal Monitor TOCO & US Transducer:

Correctly plug and unplug the probe: When plugging and unplugging the TOCO and US probes, hold the plug of the probe, align it with the corresponding interface on the monitor, and insert or unplug it smoothly and vertically. For the TOCO probe, pay attention to the position of the card slot of its interface and ensure that the probe is fully inserted into the card slot to ensure the stability of the connection. For the US probe, be careful not to twist the cable with excessive force when inserting it to prevent damage to the internal circuit.

Check after replacement
- Connection stability check: After replacing the probe, check whether the connection between the probe and the monitor is stable. Gently pull the probe cable to check if there is any looseness. For TOCO probes, you can judge whether the connection is good by observing whether it is correctly positioned in the card slot. For US probes, in addition to checking the interface connection, you should also pay attention to whether the cable is entangled or squeezed to ensure that signal transmission is not affected.

 

 

 

 

 

 

 

 

Thanks for your interest in Edan F6 Fetal & Maternal Monitor TOCO & US Connector Interface Assembly 21.53.451265-1.0 used, please feel free to contact me. Thank you for your time and wish you have a happy life.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company China World Technology Medical Equipment Service Group
Location TianHe District,GuangZhou,GuangDong
Contact Person Kiara

Request A Quote

Please check your email address.
Your message must be at least 20 characters.