City MOX3 MOX-3 Medical Oxygen O2 Gas Sensor For Mindray SV300 Wato EX 65 ventilator

Price Negotiable
Price: Negotiable
MOQ: 1 pcs
Delivery Time: 3-5 working days
Brand: City
Product Description

City MOX3 Medical Oxygen O2 Gas Sensor

 

 

Specification of City MOX3 Medical Oxygen O2 Gas Sensor

 

Product Name City MOX3 Medical Oxygen O2 Gas Sensor
Brand City
Model Number MOX3 MOX-3
Operating Principle Partial pressure electrochemical
Output 9 mV to 13 mV in 210 mBar O2
Measurement Range 0 mBar to 1500 mBar O2
Temperature Compensation <2% O2 equivalent (0°C to 40°C)
Connector UK Data Socket AMP (P/N 5520257-2)
Housing Material White ABS
Weight 42 g
Typical Applications Critical care anesthesia
Operating Temperature Range -20°C to +50°C
Operating Pressure Range 0.5 Bar to 2.0 Bar
Operating Humidity Range 0% to 99% RH noncondensing

 

NOTE

Specifications are based on cylinder gas measurements at 20 °C, 50% relative humidity, 1013 mBar and flow rate 100 ml/min-1 using the circuit recommended by City Technology. It represents the performance of the sensor during the first 3 months of service.

 

Note : Using regression coefficients, the best fit straight line is better than 0.9995 when measured over 4 data points tested with 100% N2, 21% O2, 60% O2 and 100% O2.

 

 

 

Intended Use

City MOX3 Medical Oxygen O2 Gas sensors are designed to monitor oxygen pressure in anaesthesia (excluding xenon), intensive care, neonatal incubators and general oxygen monitors.

 

Stabilization Time

 

Allow at least 15 minutes for the equipment to stabilize before calibrating or refer to the manufacturer's instructions.

 

Cleaning and Sterilization

 

If the sensor becomes dirty, it should be cleaned with distilled water and allowed to air dry.

 

Calibration Interval

 

City MOX3 Medical Oxygen O2 Gas sensors are designed to have minimal drift throughout their life. If dropped, it should be isolated for 24 hours and checked using a two-point calibration.

 

Mechanical Installation

 

When installing the sensor, the sensor should be hand-tightened to ensure tightness. .

 

 

Size of City MOX3 Medical Oxygen O2 Gas Sensor

 

 

 

 

 

NOTE

Connections should only be made using recommended coupling parts. Soldering the sensor will damage the sensor and void the warranty. For more information on connecting external load resistors and recommended coupling components, see OP-04 Principle of Operation or contact City Technology. All performance data is based on measurements with bottled gas using a flow rate of 100 mL/min. Conditions are 20 °C, 50 % relative humidity and 1013 mBar. Contact City Technology for sensor performance data under other conditions. Performance characteristics describe the performance of the sensor as supplied for the first three months. The output signal may drop below the lower limit over time.

 

 

Thank you so much for your attention .If you're interested in City MOX3 MOX-3 Medical Oxygen O2 Gas Sensor For Mindray SV300 Wato EX 65 Ventilator ,feel free to contact us .Thank you .

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company China World Technology Medical Equipment Service Group
Location TianHe District,GuangZhou,GuangDong
Contact Person Kiara

Request A Quote

Please check your email address.
Your message must be at least 20 characters.