GETINGE O2 cell serve ventilators Oxygen Battery 6640044 Upgrade Medical Equipment Supply with Patient Monitor Parts
GETINGE O2 cell serve ventilators Oxygen Battery 6640044 Upgrade Medical Equipment Supply with Patient Monitor Parts
GETINGE O2 cell serve ventilators Oxygen Battery 6640044 is a Original Medical Device Battery Specifications,Medical Device Battery Specifications.Energy supply unit for medical equipment with replaceability and energy storage function. Ensures continuous operation of medical devices during clinical procedures.
|
Attribute |
Value |
|
Brand |
GETINGE |
|
Product Name |
Oxygen Battery |
|
Model |
6640044 |
|
Condition |
Original |
|
Material |
Plastic |
|
Color |
white |
|
MOQ |
One Piece |
|
Payment Terms |
T/T(wire transfer), Western Union, Paypal |
|
Warranty |
90 days |
This OEM GETINGE Oxygen Battery (Model 6640044) provides fail-safe power redundancy for SERVO-i/SERVO-u ventilator series, ensuring uninterrupted respiratory support during critical care scenarios. Manufactured to medical-grade standards (ISO 13485:2016 certified), this white polycarbonate-encased power unit delivers peak performance with integrated safety protocols.
Technical Specifications & Validation
|
Attribute |
Specification |
|
Chemistry |
Lithium-ion (LiFePO₄) |
|
Nominal Voltage |
14.8V DC |
|
Capacity |
6600mAh (97.68Wh) |
|
Cycle Life |
≥500 cycles (80% capacity retention) |
|
Operating Temp |
5°C to 40°C (41°F to 104°F) |
|
Shelf Life |
12 months from 2026-05-15 production date |
Intelligent Power Management System
Core Functionality:
Automatic Failover: Seamless AC-to-battery transition in <15ms during power interruptions
Real-time Monitoring: 4-stage LED capacity indicator (25% per bar) with low-battery
Multi-Layer Protection:
Overcharge/discharge cutoff
Short-circuit lockdown
Temperature-triggered current limitation
Performance Advantages vs. Generics:
|
Parameter |
OEM 6640044 |
Generic Equivalent |
|
Ventilator Runtime |
4.5–5.5 hours* |
2–3 hours |
|
Recharge Cycles |
500+ |
≤300 |
|
Safety Certifications |
IEC 62133-2:2017 |
Non-compliant |
|
*At continuous 6L/min O₂ flow with 15 BPM setting |
|
|
Clinical Operation Protocols
Installation Procedure:
Safety Check: Verify hands are dry and grounded
Alignment: Position battery label-side up, aligning grooves with ventilator's docking rails
Engagement: Slide firmly until audible click confirms magnetic latching
Verification: Confirm 4-bar status on ventilator control panel
Removal Protocol:
Depress recessed release button (tactile feedback confirms activation)
Slide unit outward using thumb ridges - never pull wiring harness
Immediately place in static-shielding bag during transport
Advanced Maintenance Regimen
Optimal Charging Practice:
Partial Cycling: Maintain 40-60% charge during storage (extends lifespan 200%)
Reconditioning: Full discharge/charge every 6 months to calibrate fuel gauge
Storage Temp: 15°C–25°C (59°F–77°F) in 30-50% humidity
Critical Safety Contraindications
Fire Prevention Protocol:
Maintain 5-meter (16.4 ft) radius clearance from:
Oxygen tents
Alcohol-based sanitizer stations
Electrocautery equipment
Mandatory installation of Li-ion fire containment bag (e.g., Li-ion Fire Bag®) in storage areas
Operational Restrictions:
|
Scenario |
Required Action |
|
Nocturnal ventilation |
Dual batteries + AC power mandatory |
|
Transport monitoring |
Max 2 units per containment case |
|
Post-impact damage |
Immediate quarantine & testing |
Endurance Validation Testing
This unit passes GETINGE's 72-hour stress protocol:
Deep Discharge Test: 0% to shutdown voltage (10.5V) with 2A load
Rapid Charge Verification: 0-80% in 55 mins (certified charger)
Thermal Cycling: -20°C to 50°C ambient temperature exposure
Vibration Resistance: 5G RMS random vibration per MIL-STD-810G
Procurement & Logistics
Package Includes:
GETINGE 6640044 Battery (2026-05-15 production batch)
ESD-safe transport container with humidity indicator
Certificate of Conformance (Trace# [REDACTED])
Compliance Documentation
EU MDR 2017/745 Annex VIII
FDA 21 CFR Part 870.2700
UN38.3 Transport Certification
RoHS 3 (2015/863/EU) Test Report
Clinical Impact Statement
"During our hospital's generator failure, four SERVO-u ventilators with these batteries maintained ECMO support for 217 minutes - exceeding OEM runtime claims. Their precise fuel gauging prevented unexpected shutdowns."
– Biomedical Engineering Director, University Hospital
Actionable Next Steps
Contact our life-support specialists for:
① Batch-specific test reports
② Ventilator compatibility verification
③ Hospital battery rotation program templates
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.