GE Pump For Tonoport Gas Monitor 2002865-003 Original New Flow Control Hospital Accessories And Spare Parts
Original new flow control hospital accessories and spare parts designed for GE Tonoport Gas Monitoring systems.
| Attribute | Value |
|---|---|
| Product Name | Pump |
| Model | 2002865-003 |
| Condition | New original |
| MOQ | 1 Piece |
| Type | Spare parts |
| Size | Small |
| Weight | Light |
| Delivery Methods | DHL/Fedex |
| Warranty | 90 Days |
The pump for Tonoport 2002865-003 Original GE Tonoport Gas Monitor is specifically designed for the Tonoport gas monitoring system. As the device's "power heart," it drives precise gas flow within the monitoring circuit, ensuring stable and efficient delivery of sample gas to the detection module.
- Precision Airflow Drive: Provides stable airflow pressure and flow, ensuring gas samples enter the sensor detection area evenly and continuously.
- Low-Noise Operation: Silent design with operating noise level ≤45dB, suitable for quiet medical environments.
- Interference-Resistant Airflow Control: Precise flow control valve maintains stable airflow despite varying pipeline conditions.
- Fast Start and Stop Response: Reaches preset flow rate in ≤2 seconds and shuts off within 1 second after stop command.
| Parameter | Value |
|---|---|
| Product Name | Pump |
| Part Number | 2002865-003 |
| Applicable Machine | GE Tonoport Gas Monitor |
| Rated Voltage | 24V DC |
| Rated Power | 35W |
| Flow Range | 0.5-2 L/min (adjustable) |
| Pressure Range | 5-15kPa |
| Operating Noise | ≤45dB |
| Continuous Operating Life | ≥10,000 hours |
| Dimensions | 120mm × 80mm × 60mm (L × W × H) |
| Weight | 450 ± 20g |
A1: The pump does not require special tools. It uses standard clips and screws for installation and can be installed using standard maintenance tools (such as a Phillips screwdriver or wrench). Installation takes approximately 15 minutes.
A2: Under normal use, the flow accuracy will degrade by ≤3% over the first 5,000 hours. After cumulative operation exceeds 8,000 hours, flow calibration is recommended (calibration interval is every 2,000 hours) to maintain monitoring accuracy.
A3: First, check the piping for blockage and correct the problem. Then, disconnect the power cord for 30 seconds and then reconnect it. The pump will automatically reset and resume normal operation without the need to manually press the reset button.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.