Mindray N1 Monitor NIBP Tracheal Components pneumatic circuit Assembly Used NIBP parts Medical Parts
Pneumatic circuit assembly used for NIBP parts in medical applications. Compatible with Mindray N1 monitors.
| Attribute | Value |
|---|---|
| Product Name | NIBP Tracheal Components |
| Application Machine | Mindray N1 |
| Condition | Used-good |
| MOQ | 1 Piece |
| Color | White |
| Size | Small |
| Weight | Light |
| Warranty | 90 Days |
| Payment | Bank TT /Paypal/Western Union |
| Delivery Methods | DHL/Fedex |
The NIBP air circuit assembly for the Mindray N1 monitor is a disassembled accessory used for non-invasive blood pressure measurement. This functional used component connects the NIBP pump, cuff, and pressure sensor to form a complete gas flow and signal transmission channel.
Featuring a modular design that fits the compact structure of the N1 monitor, this assembly ensures tight and stable gas transmission for accurate blood pressure measurements.
- Gas Transmission and Sealing: Sealed tube ensures sufficient pressure during measurement for accurate pressure fluctuation capture
- Pressure Signal Transmission: Prevents signal attenuation or distortion during cuff deflation
- One-way Flow Control: Integrated valve prevents pressure drops and ensures steady cuff pressure increase
- Connectivity: Standardized interface allows quick docking with NIBP pumps and cuffs (tensile strength ≥ 50N)
| Product Name | NIBP Tracheal Components |
| Application Machine | Mindray N1 |
| Components | Medical PVC tubing, one-way valve, Luer lock connector, pressure-transmitting branch line |
| Tubing Specifications | Inner diameter 2.5mm ± 0.1mm, wall thickness 0.8mm, length 600mm ± 50mm |
| Maximum pressure rating | 300mmHg (no leaks) |
| Connection type | Standard Luer lock connector (compatible with Mindray NIBP cuffs) |
| Disinfection | Wipe with 75% alcohol (≤30 times per day) |
| Lifespan | ≥5000 measurement cycles |
A1: Slow cuff inflation, sudden pressure drop during measurement, monitor displaying "Insufficient Pressure," or measurement failure may indicate a leak.
A2: Replace when: ① Airway surface is hardened, cracked, or inner wall is sticking; ② Connector is worn causing loose insertion; ③ Surface damage from repeated disinfection affects biocompatibility.
A3: Wipe surface and connector with 75% alcohol after each use (prevent interior seepage). Weekly check for kinks/blockages with air blow test. Store away from sunlight and oils.