Mindray IPM-9800 SPO2 Plate 050-00046-00 110mm×90mm×1.6mm

Price Negotiable
Price: USD
MOQ: 1 Piece
Delivery Time: 3-5 working days
Brand: Mindray
Product Description
Mindray IPM-9800 Monitor SPO2 Plate 050-00046-00 051-000058-00
The Mindray IPM-9800 Monitor SPO2 Plate includes two models: 050-00046-00 and 051-000058-00. The 050-00046-00 focuses on signal processing, while the 051-000058-00 focuses on interface drivers. Together, they form a complete blood oxygen monitoring unit, the core hardware for accurate SpO₂ and PR measurements. Their materials and circuit design fully meet the stringent requirements of medical equipment for stability, interference immunity, and safety.
Product Specifications
Product name SPO2 Plate
Model Mindray IPM-9800
PN 050-00046-00 051-000058-00
Circuit board material Medical grade FR-4 epoxy glass cloth laminate
Shipping time Different
Deposit 100% pay before shipping
Payment terms Bank TT/ Paypal/Western Union
MOQ 1 Piece
Size 110mm*90mm*1.6mm
Weight About 60g
Core Functions
  • Signal Acquisition and Preprocessing
  • Blood Oxygen Saturation Calculation
  • Probe Adaptation and Driver
  • Probe Status Diagnosis
Frequently Asked Questions
Q1: The device displays "SpO₂ signal weak." I've checked the probe and it's fine. Is the oximeter board faulty?
A1: Turn off the power and check if the power cord is securely plugged in. After powering on the device, enter maintenance mode and check the oximeter board self-test results. If it displays "Signal amplification circuit abnormality" (fault code E04), the oximeter board is faulty and should be replaced.
Q2: Can the two oximeter boards be replaced separately? Or must they be replaced together?
A2: They can be replaced separately, depending on the fault type: ① If "Probe cannot be recognized" or "Drive current abnormality" occurs, it's likely that the 051-000058-00 board is faulty and can be replaced alone. ② If "Oximeter calculation error is large" or "Weak signal cannot be calibrated" occurs, it's likely that the signal processing chip or filter circuit on the 050-00046-00 board is faulty and should be replaced alone. ③ After replacement, power on the device and perform "SpO₂ calibration" to ensure measurement accuracy meets requirements.
Q3: The blood oximeter board gets noticeably hot while operating (approximately 65°C to the touch). Is this normal?
A3: It's not normal. The normal operating temperature should be ≤60°C. Possible causes of abnormal heating: ① The heat sink may have fallen off or the thermal grease may have dried out. Disassemble the device to inspect the heat sink on the 050-00046-00 board and reapply thermal grease (0.5mm thick). ② The driver chip is overcurrenting. Measure the probe LED current to see if it exceeds 80mA.
Product Images
Mindray IPM-9800 Monitor SPO2 Plate front view Mindray IPM-9800 Monitor SPO2 Plate side view
Ordering Information
Payment Methods Bank Transfer / PayPal / Western Union
Shipping Methods DHL / FedEx

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company China World Technology Medical Equipment Service Group
Location TianHe District,GuangZhou,GuangDong
Contact Person Kiara

Request A Quote

Please check your email address.
Your message must be at least 20 characters.