GE OEM Cardiac Displacement Cable 3.0 Meters Length 4.0mm Diameter 150,000 Bending Cycles for Vivid E95 S70 Logiq E9

Price Negotiable
Price: USD
MOQ: 1 Piece
Delivery Time: 3-5 working days
Brand: GE
Product Description
GE Cardiac Displacement Cable 16590-HEL LOT S20302 New original
The GE Cardiac Displacement Cable 16590-HEL is an original equipment manufacturer (OEM) medical-grade cardiac displacement signal transmission cable, serving as an auxiliary component for cardiac ultrasound, ECG monitoring, and other related equipment. This cable connects cardiac diagnostic equipment and sensors or probes, transmitting acquired cardiac signals to the mainboard of the ultrasound device.
Product Features
  • Accurate and Distortion-Free Signal Transmission: The cable conductor uses high-purity oxygen-free copper, ensuring stable and complete signal transmission.
  • Strong Anti-Interference Design: The cable features a double-shielded structure, unaffected by external electromagnetic interference in complex environments, ensuring stable data transmission and making it suitable for use in operating rooms, ICUs, and other demanding settings.
  • High Durability: The outer layer of the cable is made of medical-grade wear-resistant and tensile-resistant PU material, withstanding repeated bending during daily operation to prevent conductor breakage, making it suitable for frequently used medical environments.
Technical Specifications
Name Cable
Model 16590-HEL
Compatible with GE Vivid E95, Vivid S70, Logiq E9, CardioLab etc.
Material Conductor: High-purity oxygen-free copper
Outer layer: Medical-grade PU material
Cable length 3.0 meters
Cable diameter 4.0mm
Cable weight Approximately 120g
Bending life ≥ 150,000 cycles
Insertion/extraction life ≥ 5,000 cycles
Condition New original
GE Cardiac Displacement Cable 16590-HEL product image Close-up view of GE Cardiac Displacement Cable 16590-HEL connectors
Frequently Asked Questions
Q1: During surgery, the cable became contaminated with blood. How should I properly disinfect it to avoid damaging the cable?
A1: Immediately disconnect the cable from other devices. Wipe the surface of the cable clean to prevent liquid from entering the cable. Then, wipe the entire cable with a soft cloth containing disinfectant, keeping it moist for 10 minutes. Wipe it with sterile water and dry it. Check the cable for damage; if damaged, use it immediately.
Q2: After long-term use, the cable connector has become slightly loose, and signal interruptions occasionally occur when plugging and unplugging. How can this be resolved?
A2: Wrap waterproof tape around the connector and the device interface to strengthen the connection and prevent liquid seepage. Signal interruptions may be due to oxidation of the interface contacts; remove the oxide layer. If the problem is severe, the cable needs to be replaced.
Q3: The cable exhibits "signal drift," with significant fluctuations in heart displacement data. How can this be troubleshooted?
A3: If "signal drift" occurs, check if the device is near strong electromagnetic equipment such as high-frequency electrosurgical units. Move the cable away from these devices. If the problem persists, go to the device's "signal settings" menu, enable the "displacement signal filtering" function, and select the "high-intensity filtering" mode to filter out interference signals.
Ordering Information
Payment Methods Bank Transfer / PayPal / Western Union
Shipping Methods DHL / FedEx