Original Medtronic LP20 Defibrillator Paddle Pad with 2-360 J Energy Range 8mm Thickness and ≥95% Efficiency
Price:
USD
MOQ:
1 Piece
Delivery Time:
3-5 working days
Brand:
Medtronic
Product Description
Medtronic LP20 Defibrillator Paddle Pad Handle Electrodes (Original)
The Medtronic LP20 defibrillator handle electrodes are the original defibrillator handle electrodes for the LIFEPAK 20 defibrillator monitor. These essential components for cardiopulmonary resuscitation (CPR) are made of conductive and ergonomic materials that release energy through patient contact to achieve emergency defibrillation. Critical for saving lives in emergency departments, ambulances, and ICUs.
Key Features
- Graded Conductivity Design: High-conductivity material with conductive coating ensures effective energy transfer for deep tissue stimulation.
- Dual-Mode Adaptability: Integrated adult/pediatric design eliminates need for component changes during emergencies.
- Safety Protection: Rounded edges prevent skin damage; insulated handles protect operators from shock.
- Integrated Monitoring: Built-in ECG contacts enable real-time heart rhythm monitoring without additional leads.
Technical Specifications
| Parameter | Value |
|---|---|
| Compatible Device | LIFEPAK 20 |
| Patient Group | Adults/Pediatrics |
| Energy Range | 2-360 J |
| Electrode Thickness | 8mm |
| Energy Transfer Efficiency | ≥95% |
| Handle Weight | Approx. 500g |
| Cable Length | 2.0 meters |
| Insertion Lifespan | ≥5000 cycles |
| MOQ | 1 SET |
| Delivery Time | 7-10 days (DHL) |
Product Images
Frequently Asked Questions
Q: Sparks appear during use. What causes this and how should it be handled?
A: This occurs due to insufficient conductive gel, dry skin, or poor contact. Immediately stop defibrillation, check for burns, clean with saline, reapply sufficient gel ensuring full contact without air bubbles, then resume.
Q: Device shows "Electrode mode mismatch" in pediatric mode. How to troubleshoot?
A: Verify the mode switch is fully engaged and connections are secure. Clean contacts and reconnect firmly. Restart device and retry mode switch. If issue persists, replace handle/electrode.
Q: Conductive coating is peeling. Does this affect functionality?
A: Minor peeling may allow temporary use with extra gel, but significant peeling exposing metal substrate requires immediate replacement to prevent burns or ineffective treatment.
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
China World Technology Medical Equipment Service Group
Location
TianHe District,GuangZhou,GuangDong
Contact Person
Kiara