Edan F2 fetal monitor alarm indicator board display connection cable 01.13.114335
Edan F2 fetal monitor alarm indicator board display connection cable 01.13.114335
► Brief Description
The alarm indicator board cable is a flexible cable marked with part number 01.13.114335 for easy identification from other cables. Both ends have white ribbon cable connectors; one end connects to the alarm light board, and the other to the monitor's display panel. The cable is very strong and durable, and its flexibility allows it to be folded or bent freely. Its length is approximately 10 cm.
The primary function of the 01.13.114335 cable is to ensure that all alarm commands and status signals processed by the main unit are transmitted to the indicator board in real-time with zero error, illuminating the corresponding indicator lights or triggering audible alerts. Simultaneously, it accurately transmits user commands via the indicator board buttons back to the monitor.
► Specifications
| Brand: | Edan |
| Product Name: | alarm indicator board cable |
| Warranty: | 90 Days |
| Part number | 01.13.114335 |
| Payment term: | Full before shipment |
| Delivery Method: | DHL ,Fedex ,UPS |
| Delivery: | 3-5 Working days |
| MOQ: | 1 Piece |
| Use for | EDAN F2 fetal monitor |
| Color | White |
| Packing: | Carton |
| Color: | White |
| Inventory: | In stock |
| Condition: | In Good Working |
►Detailed Photos
►Function of alarm indicator board cable
1. Signal and Command Transmission Channel
Alarm Signal Transmission: When the monitor detects abnormalities (such as excessively fast or slow fetal heart rate, excessively strong contractions, probe detachment, etc.), the main control board sends an electrical signal to the alarm indicator panel via this cable.
Control Command Transmission: It may also transmit user operation commands such as "mute" or "light test".
Power Supply: Provides the necessary power for the LED indicators, buzzers, or speakers on the alarm indicator panel.
2. Visual Alarms: Illuminates LEDs of different colors (usually red/yellow) corresponding to different alarm levels and types, making it easy for medical staff to understand.
3. Auditory Alarms: Triggers the buzzer or speaker to emit alarm sounds of different frequencies and rhythms, attracting attention even when out of the medical staff's sight.
4. System Status Indicators: May also include power indicator lights, equipment operation status lights, etc.
►Maintenance
1. Any operation involving opening the equipment casing or replacing internal cables must be performed by trained technical personnel to ensure safety and equipment sealing.
2. Always use original manufacturer or certified cables with the serial number 01.13.114335 during maintenance to ensure compatibility and safety.
3. During routine equipment maintenance, inspect the physical condition of the cable and its connectors for looseness, wear, or creases.
►Warrany:
The connection of the wires must be made under power-off conditions, and an anti-static wrist strap must be worn.
Thank you for taking time to know our Edan F2 fetal monitor alarm indicator board display connection cable 01.13.114335 product, if you are interested , please let me know, Wish you have a good life.