M1657B PHiliph Water Trap for ETCO2 Monitor Anesthesia Machine Gas Sampling Line

Price Negotiable
Price: USD
MOQ: 1
Delivery Time: Negotiable
Brand: PHiliph
Product Description

M1657B PHiliph Water Trap for ETCO2 Monitor Anesthesia Machine Gas Sampling Line


  • Product Description

 

The M1657B Water Collection Cup is a specialized accessory designed for PHiliph monitors, serving as a critical component in sidestream End-Tidal CO2 monitoring systems. Constructed from transparent polycarbonate, it features a compact design with a blue locking latch and a clear gas flow arrow. Its primary function is to trap condensation water generated in the gas sampling line, preventing moisture from entering the sensitive sensor, thereby protecting the equipment and ensuring measurement accuracy.

 

 

 

  • Product Specifications

 

Product Name Water Trap
Model M1657B
Material PC
Function Condensation Trapping
Color Transparent / Blue
Sterilization Method Ethylene Oxide (EO)

 

 

  • Use Tips

 

 

1. Pre-use Inspection:

Before use, check for cracks or deformation in the cup and ensure the packaging is intact.

 

2. Confirm Flow Direction:

When installing, strictly align the arrow on the cup with the gas flow direction (usually from the patient end to the monitor end).


3. Regular Monitoring:

Regularly check the water level during use. When the water accumulates to a certain height (usually recommended not to exceed half the cup), it should be emptied or replaced promptly to prevent water backflow into the sensor.


4. Replacement Frequency:

It is recommended to replace it daily or promptly when significant water accumulation is observed to maintain pipeline hygiene.

 

  • Precautions

1. Do not sterilize this product using high-pressure steam, as it may cause plastic deformation.
2. Do not store or use in environments exceeding 40°C for prolonged periods.
3. Discontinue use immediately if the cup body cracks or the latch is damaged.

 