Wiring Between The Display Board And Main Board of PHiliph TC10 ECG Machine 2.5 Cm Wide And 15 Cm Long

Price Negotiable
Price: Negotiable
MOQ: 1
Delivery Time: 3-5 working days
Brand: PHiliph
Product Description

Wiring Between The Display Board And Main Board of PHiliph TC10 ECG Machine 2.5 Cm Wide And 15 Cm Long

 

 

Introduction

 

The flexible flat cable inside the PHiliph TC10 ECG machine is the core link connecting the motherboard and the display control board. The output display screen, ECG waveform data, system control commands, and basic power supply signals all pass through it for bidirectional transmission. It is a key component ensuring stable screen illumination and clear data display.

 

 

Main Functions

 

1. Signal Transmission Channel: Serving as a dedicated link between the motherboard and the display board, it synchronously transmits ECG waveform data, system control commands, and screen power signals, enabling the screen to display device operating status and inspection results in real time and stably.

 

2. Flexible Adaptive Connection: The flat, flexible design adapts to the limited installation space inside the device, while withstanding slight bends during device opening, closing, and transportation, ensuring uninterrupted signal transmission.

 

3. Rapid Fault Repair: Replaces aging or damaged old cables, directly resolving issues such as screen not lighting up, screen flickering, data asynchrony, and display lag, restoring the device to normal operating status.

 

Usage Precautions

 

1. All disassembly and assembly operations must be performed with the device completely powered off. Hot-plugging or unplugging can cause irreversible damage to the motherboard or display board interfaces due to instantaneous current surges.

 

2. When plugging or unplugging ribbon cables, always hold the reinforcing plate or the base of the ribbon cable. Do not pry the interface with sharp objects to prevent pins from bending or breaking.

 

3. If the device exhibits screen abnormalities, do not repeatedly turn the device on and off or hit it. First, check if the ribbon cable is loose or damaged, and replace it promptly to avoid damaging the motherboard or display board by using the faulty device.

 

4.Reduce bending and pulling of the cable to extend its service life.