Edan CADENCE II Fetal Monitor Display AWG-f32240 HSGWT-C 1008 M2010060302 Spare Part
Edan CADENCE II Fetal Monitor Display AWG-f32240 HSGWT-C 1008 M2010060302
► Brief Description
The Edan CADENCE II Fetal Monitor Display, part number AWG-f32240 HSGWT-C 1008 M2010060302, is gray and made of metal. This 6-inch display has a 320×240 QVGA resolution and features a transflective display mode, maintaining clear visibility in both bright and low-light environments. The horizontal and vertical viewing angles can reach approximately 35°, and the entire device supports free adjustment of the screen within a 60° angle range to accommodate different viewing postures such as standing, sitting, and side-viewing.The display panel surface is treated to resist fingerprints, scratches, and abrasion, and can withstand frequent wiping with commonly used medical disinfectants such as alcohol and disinfectants, meeting the stringent cleaning and disinfection requirements of obstetric clinics.
► Specifications
| Model | AWG-f32240 HSGWT-C 1008 |
| Brand | Edan |
| Product Name | Display |
| Condition | Original |
| MOQ | 1 piece |
| Delivery Method | DHL ,Fedex ,UPS |
| Payment Method | Paypal,T/T,Western Union |
| Warranty | 90 Days |
| Use for | Edan CADENCE II Fetal Monitor |
| Type | Spare part |
| Payment Terms | Full Before Shipment |
| Inventory | In stock |
| Size | 6 Inch |
| Color | Grey |
►Detailed Photos
►Core Display Functions and Clinical Value
1. The display screen receives signals such as fetal heart rate, uterine contraction pressure, and fetal movement count from the motherboard in real time, presenting them synchronously in a triple format of "high-smoothness curve + numerical value + indicator symbol". Abnormal fluctuations are automatically highlighted to help medical staff quickly identify the risk of fetal distress.
2. The display screen can replay up to 12 hours of historical data, facilitating continuous analysis of monitoring trends and traceability comparison throughout the monitoring process. It assists in assessing placental function and fetal oxygen reserve status.
3. The display screen integrates a full-function menu including power-on self-test, monitoring parameter settings, alarm threshold configuration, thermal recorder printing control, and wireless network configuration. The real-time status bar synchronously displays battery level, power supply mode, probe connection status, and various alarm information.
►FAQ:
Q1. Is the display original for the Edan Cadence II fetal monitor?
A1. This is an original OEM display module. While it may be pulled from a test unit or overstock, every single unit undergoes a strict multi-point quality inspection . We provide a pre-shipment testing video for your peace of mind.
Q2.How to ensure the display quality?
A2.It has a 90-day warranty, and a test video will be provided for confirmation before shipment.
Q3.Which international courier service to use?
A3.DHL ,Fedex ,UPS are available, and also can use your own freighter.
All spare parts are rigorously tested in our ISO-certified facility before shipment.
Thank you for reviewing our product. If you need a replacement display for your Edan CADENCE II Fetal Monitor, please contact us for an immediate quote.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
