Mindray D3 defibrillator parameter module Top board 050-000324-80850 051-000230-00 Working well

Price Negotiable
Price: USD
MOQ: 1 Piece
Delivery Time: 3-5 working days
Brand: Mindray
Product Description

Mindray D3 defibrillator parameter module Top board 050-000324-80850 051-000230-00

 
 
► Brief Introduction
 

This is the upper acquisition board in the parameter module of the Mindray D3 defibrillator, part number 050-000324-80850 051-000230-00.

This acquisition board is located at the top of the entire module assembly, paired with the base plate below, forming the complete ECG & human impedance acquisition module of the D3 defibrillator.

The acquisition board is made of PCB board material, with a yellow high-voltage insulation strip on the surface to separate the high-voltage circuit from the low-voltage circuit, preventing high-voltage electricity from damaging the low-voltage circuit during defibrillation and ensuring the normal operation of the defibrillator.

 
 
Features


1. High ECG Acquisition Accuracy

Employs multi-channel independent ECG signal acquisition, accurately capturing minute ECG waveforms, avoiding misjudgments or incorrect discharge suggestions, and improving emergency safety.

2. Double-Layer High-Voltage Isolation

The circuit board uses double-layer protection to isolate high-voltage areas, ensuring safe defibrillation; the front uses an ink-based area to isolate the high-voltage area, while the back provides double protection against high-voltage discharge, ensuring the circuit board will not be burned out.

3. High Impedance Detection Efficiency

Employs an independent impedance detection channel to monitor electrode contact status in real time. An immediate alarm pops up if the electrode shifts, dries out, or detaches, preventing missed detection of dangerous heart rhythms due to signal loss.

4. Modular and Convenient Design

Utilizes a separate upper and lower board design, saving troubleshooting time and maintenance costs. Only the corresponding faulty acquisition board needs to be replaced, eliminating the need to replace the entire acquisition board and reducing maintenance costs.



► Parameters
 

Product name

Top board

P/N

050-000324-80850 051-000230-00

Compatible machine

D3

Material

PCB board

Condition

Working well

Warranty

90 days

Color

Green

Weight

About 160g

Delivery time

7-10 days

Shipping method

By DHL,FedEx

MOQ

1 piece

 
 
► Product Picture
 


 


►FAQ
 

Q1: The AED analysis directly indicates "signal loss," with no hardware errors reported. Which component on the circuit board is likely to cause this fault?

A1: It may be a fault in the circuitry responsible for electrode input on the upper acquisition board, preventing the original ECG signal from being transmitted to the chip. Replacing the entire upper board will restore signal acquisition.

 

Q2: The defibrillator's ECG waveform drifts significantly, even after replacing the electrode pads. Which part of the parameter module is faulty?

A2: First, check if the baseboard cable is pressing against the circuit board. If external components are normal, the signal amplification channel operational amplifier on the upper board is aging, causing unstable signal sampling. Replacing the upper acquisition board will resolve the waveform drift.

 

Q3: The pin header on the side of the upper plate has slight oxidation and blackening. Can it be repaired by grinding and reused?

A3: Grinding can only remove the oxide layer temporarily. In the humid environment of the delivery room, oxidation will quickly recur, causing the ECG waveform to disappear intermittently. It is recommended to replace the acquisition plate directly.


90 Day Warranty                             SGS ceryification

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company China World Technology Medical Equipment Service Group
Location TianHe District,GuangZhou,GuangDong
Contact Person Kiara

Request A Quote

Please check your email address.
Your message must be at least 20 characters.