MAQUET Ventilator Water Trap 6695105 for Hospital Device Use Accessories New original Condition
MAQUET Ventilator Water Trap 6695105 for Hospital Device Use Accessories New original Condition
► Brief Introduction
This is a condensate collection cup for the Maquet ventilator. It is a single-use consumable, part number 6695105. This cup collects condensate from the ventilator's breathing circuit and is installed in the patient's tubing to prevent backflow of condensate and waste fluid.
It is individually packaged in a disposable sealed bag to ensure the cup remains clean and uncontaminated.
The cup is made of PP plastic, is heat-resistant for sterilization, highly durable, and not easily broken. Its transparent body allows for easy observation of the water level and timely replacement.
► Features
1. Collects condensate from the breathing circuit
After the ventilator humidifies, the tubing produces a large amount of condensate. The collection cup collects and traps this water, preventing backflow into the patient's airway and the risk of choking and suffocation.
2. Protects the ventilator's precision sensing components
Prevents backflow of condensate and sputum into the expiratory flow sensor, avoiding water damage to the sensor and corrosion of the diaphragm, reducing the probability of equipment malfunction alarms.
3. Maintaining Airtightness of the Ventilation Circuit
The accumulator cup is equipped with a standard tubing interface, ensuring no air leakage after assembly and guaranteeing accurate monitoring of ventilator pressure and tidal volume, without parameter drift alarms.
4. Visualized Water Level Observation
The white, semi-transparent cavity allows medical staff to visually view the water level without disassembly, enabling timely replacement of the accumulator cup.
► Parameters
|
Product name |
Water trap |
|
Model/Part number |
6695105 |
|
Use for |
Ventilator |
|
Material |
PP plastic |
|
Condition |
New original |
|
Warranty |
90 days |
|
MOQ |
1pc |
|
Shipping method |
By Express |
|
Payment |
100% advanced |
► Product Picture
►FAQ
Q1: What malfunctions will occur if the accumulator cup is full and not emptied promptly?
A1: Water overflows into the circuit, causing damage to the flow sensor, ventilator leak alarms, inaccurate tidal volume monitoring, and in severe cases, water flow impacting the patient's airway.
Q2: Can this accumulator cup be re-sterilized and reused?
A2: The PP material supports multiple high-temperature sterilizations, but long-term use may lead to aging, cracking, and poor sealing. Regular replacement with a new product is recommended.
Q3: Frequent flow deviation reports from the device; is this caused by a malfunctioning accumulator cup?
A3: Leaks in the accumulator cup and water overflow into the sensor will both trigger flow alarms. First, check the condition of the accumulator cup.
Q4: Are there any requirements for the installation location of the condensate collection cup?
A4: It needs to be installed at the lower position of the patient's tubing to ensure that condensate flows naturally into the water storage chamber. Installation at a higher position will not allow it to collect water.