PHILIPH Goldway SpO2 Module 865498 G21, SpO2 Parameter Module for G30E, G40E, and G60E Monitors
PHILIPH Goldway SpO2 Module 865498 G21, SpO2 Parameter Module for G30E, G40E, and G60E Monitors
► Brief Introduction
This is a SpO2 monitoring module manufactured by Goldway, part number 865498, version G21.
This module is configured for PhilipH Fast-SPO2 monitoring and is a built-in module for patient monitors. It features a foolproof snap-fit design, allowing for easy plugging and unplugging. It is quick and convenient to install and remove, and is compatible with Goldway G-series monitors, including models G30E, G40E, G50E, G60E, and G70E. It is a core hardware unit for blood oxygen detection in these devices.
► Features
1. Blood Oxygen Data Acquisition: Receives raw signals from the blood oxygen probe, processes them using algorithms, and outputs SpO2 data and waveforms to the monitor screen, enabling real-time monitoring of the patient's blood oxygen level.
2. FAST Anti-Interference: Equipped with the FAST-SpO2 algorithm, it suppresses interference from limb tremors and strong ambient light, maintaining stable monitoring even under poor external conditions and reducing invalid alarms and data fluctuations.
3. Fault Self-Check and Alarm Signal Output: The module automatically performs a self-check upon power-on. In case of probe detachment, signal abnormality, or module hardware failure, it sends a fault signal to the monitor's main control board, facilitating rapid fault location by medical staff.
4. Modular Solderless Replacement: The slot-type plug-and-play design eliminates the need for complete disassembly of the entire unit in case of module failure; simply remove and replace the module. After replacement, no complex calibration is required; the entire unit can be put into clinical use after a self-check, minimizing equipment downtime for maintenance.
► Parameters
|
Product name |
SpO2 Module |
|
Machine model/PN |
G21/865498 |
|
Condition |
Used but working well |
|
Warranty |
90-day |
|
Material |
Plastic cover |
|
Size |
Small |
|
Weight |
1.0kg |
|
Shipping time |
7-10 days |
|
Lead time |
3-5 working days |
|
Payment by |
Paypal, Bank transfer, Western Union |
► Product Picture
►FAQ
Q1: The monitor's SPO2 sensor is intact, but it keeps reporting a SPO2 malfunction. Is this a module failure?
A1: Not necessarily. Check for interface oxidation and replace the probe or module with a known working one. If the error persists after replacing the probe, the SPO2 module is likely faulty.
Q2: Is SPO2 calibration necessary after replacing the module?
A2: No special calibration is needed for normal replacement. If the readings deviate significantly from those of a handheld SPO2, accuracy calibration is required.
Q3: What symptoms indicate a high probability of module failure?
A3: The monitor fails its self-test for SPO2 upon power-on; there is no waveform or reading when the SPO2 sensor is plugged in; frequent reports of SPO2 sensor detachment; SpO2 values remain unchanged and do not change with the patient's condition.