PHILIPH IntelliVue MX Series Multi-parameter Module 867040, EtCO2 Press Temp Extension Module
PHILIPH IntelliVue MX Series Multi-parameter Module 867040, EtCO2 Press Temp Extension Module
► Brief Introduction
This is a multi-parameter module, part number 867040. It is an external parameter expansion module for monitors, compatible with MX series monitors, including models such as IntelliVue MX400, MX450, MX500, MX550, MX600, MX700, and MX800. It requires matching the corresponding host firmware version. The sampling method is CO2 bypass sampling; it supports adult, pediatric, and newborn modes; and it is powered by the monitoring host.
► Features
1. EtCO2 Monitoring: Real-time monitoring of end-tidal carbon dioxide and respiratory rate, displaying CO2 waveforms; used to assess patient ventilation and quickly identify intubation displacement and ventilation abnormalities.
2. Dual-Channel Invasive Pressure Acquisition:Dual invasive pressure channels allow simultaneous connection to two invasive pressure sensors; monitors arterial pressure, central venous pressure, and pulmonary artery pressure.
3. Dual-Channel Temperature Measurement:Dual temperature acquisition channels support simultaneous connection of two temperature probes, enabling multi-point temperature monitoring of the body surface and cavities.
4. Plug-and-Play Expansion:Modules snap-on connection; newly added parameters are automatically activated upon host recognition, requiring no complex setup.
► Parameters
|
Product name |
Monitor Module |
|
Machine model/PN |
867040 |
|
Condition |
Used but working well |
|
Warranty |
90-day |
|
Material |
Plastic cover |
|
Size |
Small |
|
Weight |
0.5kg |
|
Shipping time |
7-10 days |
|
Lead time |
3-5 working days |
|
Payment by |
Paypal, Bank transfer, Western Union |
► Product Picture
►FAQ
Q1: Can the 867040 be used with MP series patient monitors?
A1: No, it is only compatible with MX series patient monitors. The hardware interface and communication protocol are incompatible with MP20-MP80.
Q2: Why can't the module be recognized?
A2: 1. Oxidation or dirt on the side connector pins;
2. The host firmware version is too low;
3. The module hardware is damaged.
Q3: How to troubleshoot inaccurate CO2 readings and sampling error reports?
A3: First check if the sampling tube and water tank are clogged with water; after ruling out consumable issues, the CO2 component inside the module is most likely faulty.
Q4: Does this module need calibration after replacement?
A4: Invasive pressure channels require zeroing calibration; CO2 requires accuracy verification; body temperature generally does not require calibration; complete the system self-test.

90 Day Warranty SGS ceryification
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.