China World Technology Medical Equipment Service Group
                                                                                                           
Verified Supplier
11 Years
Since 2015
Menu

COVIDIEN Nellcorr Pulse Oxi--metry Patient Interface Cable 10Ft 3.0m REF DOC10 Oxi--Max Pulse Sensor Extension Cables

Price Negotiable
Price: Negotiable
MOQ: 1
Delivery Time: 3-5 working days
Brand: COVIDIEN Nellcorr
Product Description

 

COVIDIEN Nellcorrr Pulse Oximetry Patient Interface Cable 10Ft 3.0m REF DOC10 OXI-MAX pulse Sensor Extension Cables

 

 

► Brief Introduction

COVIDIEN Nellcorrr Pulse Oximetry Interface Cable DOC-10 is an assembly consisting of the parts of the SpO2 sensor.

Connect the cables prior to attaching to the monitor. An SpO2 reading will be displayed within moments of attaching the sensor to either a Nellcorrr simulator or to your finger.

It’s work for GE Carescape B650, GE Carescape V100, GE E-NSAT, GE Pro 1000, GE Pro 1000 V3, GE Pro 200, GE Pro 300, GE Pro Series V2, GE ProCare, GE ProCare 100, GE ProCare 200, GE ProCare 300, GE ProCare 400, GE ProCare Ausculatory 400

The SpO2 probe has a built-in sensor. When the SpO2 sensor is connected to the SpO2 connector and the patient, the probe senses heart rate and oxygen saturation. Analog signals are directed to SpO2 PWA (Nellcorrr or Masima). Analog signals are analyzed on SpO2 PWA. Results are numbered and sent to the main panel via optics interfaces. The hooks provide patient isolation as well as a serial data interface. The main panel temporarily stores data and directs it to the user interface panel for viewing and/or printer.

 


SpO2 - Nellcorrr Pulse Oximetry

SpO2 Range and Accuracy adult/neonate: 70-100% ±3.5 digits
Pulse Rate Range and Accuracy 30 - 250 BPM ±3 BPM
Saturation Pitch Indicator Pitch changes with saturation
Sensor Connect/Disconnect from Patient The Monitor detects the connection or disconnection or a
sensor to the patient within 15 seconds
Sensor Connect/Disconnect from Monitor The monitor detects the attachment or disconnection of a
sensor from the Monitor within 5 seconds
Pulse Detection The Monitor detects a pulse of enters a no-signal state
within 15 seconds of being attached to a patient
Loss of Pulse the monitor detects loss of pulse from patient and enters a
no signal state within 10 seconds

 

 

Cleaning

 

Clean the surface of the SpO2 sensor before and after each patient is used. Clean the SpO2 sensor with a slightly wet cloth with a mild cleaner. Wipe the SpO2 sensor to ensure that all detergent residues are removed.

 

Caution: Don't put isoprop alcohol on the screen - some parts may crack and crack.

 

Compatible cleaning and sterilization solutions are:

  1. Chlorinated disinfectant, 5.25%, 0.75 cups per gallon of water.
  2. Cidex Formula 7 (registered trademark of Johnson & Johnson Medical Products, Inc.) or PHiliphhilipisoHex (registered trademark of Winthrop-Breon Laboratories.)
  3. Quad-microbicide detergents such as VESTAL INSURANCE (registered trademark of Vestal Corp.), HI-TOR PLUS (registered trademark of Huntington Corp.) or VIREX (registered trademark of S.C. Johnson & Son Corp.)

For the above, follow the manufacturers' recommendations for mitigation and use rate. These recommendations are not authenticated by manufacturers or on the effectiveness of these materials in cleaning or disinfection.

 

► FAQ

 

1. Can we arrange an online meeting with existing customers?

With the customer's consent, an online meeting can be arranged to give you an authentic experience of our collaboration.

 

2. How long is a long-term cooperation agreement typically signed?

Common terms include 1 year, 2 years, or 3 years, with flexible arrangements possible based on client requirements.

 

3. Does the official website support online quotation requests?

Yes, the website provides an online quotation form with responses to quotes within 24 hours.

 

4. Are the accessory models and quantities indicated on the packaging?

Each outer box is labeled with information such as model, quantity, and batch number.

 

5. Is a market analysis report on medical accessories available?

Annual market analysis briefings can be shared with long-term partner clients.

 

Please kindly contact us, if you are interested in COVIDIEN Nellcorrr Pulse Oximetry Patient Interface Cable 10Ft 3.0m REF DOC10 OXI-MAX pulse Sensor Extension Cables, Thank you!

 


90 Day Warranty                             SGS ceryification

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company China World Technology Medical Equipment Service Group
Location TianHe District,GuangZhou,GuangDong
Contact Person Kiara

Request A Quote

Please check your email address.
Your message must be at least 20 characters.