L12-4 PHiliph Broadband Linear Array Transducer For ClearVue350 ClearVue550 ClearVue650 ClearVue850 Sparq

Price Negotiable
Price: Negotiable
MOQ: 1pcs
Delivery Time: 3-5 working days
Brand: PHiliph
Product Description

L12-4 PHiliphhilip Broadband Linear Array Transducer For PHiliphhilip ClearVue350 ClearVue550 ClearVue650 ClearVue850 Sparq ultrasound systems 

 

 

 

Specifications for PHiliphhilip L12-4 Broadband linear array transducer

 

Technology

·

Broadband

Frequency range 12 - 4 MHz
Aperture 34mm
Volume of field of view /
Applications Vascular, intervention, bowel, MSK and small parts, and superficial imaging; Cerebrovascular, periPHiliphhiliperal vascular, internal mammary vessels, and MSK imaging
Image Fusion Navigation capable No
Number of elements 128
Array Type Linear
Modes 2D, Steerable pulsed wave and color Doppler, Color Power Angio (CPA), SonoCT, panoramic, XRES, and harmonic imaging
Biopsy capable Yes
PHiliphhilipysical dimensions /

 

 

Transducer Care Safety

 

Choosing a Disinfectant

Classification Definition Level of Disinfection
Critical Device enters otherwise sterile tissue (for example, intraoperative applications) Sterilization
Semi-critical Device contacts mucous membranes (for example, intracavity applications) High
Noncritical Device contacts intact skin Intermediate or low

 

 

 

 

General Cleaning for All Transducers

 

1. After examining each patient, use a damp cloth to remove the ultrasound transmission gel from the transducer.

2. Disconnect the transducer from the system, and remove all accessories that connect or cover the transducer.

3. To remove all organics and other residues, use a pre-cleaner or cleaner to help remove protein residues. The PHiliphhilip of the enzyme cleaner should be 6.0 to 8.0. These cleaners will be further diluted during use. Follow the manufacturer's instructions for dilution. When cleaning the lens, use an ink-absorbing action instead of a wiping action.

4. To remove residual particles and cleaning residues, rinse thoroughly with water to the immersion point shown in "Disinfect the transducer by immersion" and "Disinfect the TEE transducer by Immersio"

5. Wipe with a dry cloth. To wipe the lens dry, use a soft cloth and an ink-absorbing action instead of a wiping action.

 

 

Warning

When cleaning and disinfecting any equipment, always wear protective glasses and gloves.

 

CAUTIONS

Limit the use of 70% isopropyl alcohol (rubbing alcohol) and alcohol products on the transducer. Isopropyl alcohol can damage the parts of the transducer. This damage is not covered by the warranty or your service contract.

• Wipe the end of the transducer only with isopropyl alcohol solution, up to 2.5 cm (1 inch) from the strain relief/housing connection.

• Do not use isopropyl alcohol on strain relief/housing connectors, strain relief or cables.

• Do not use isopropyl alcohol on the TEE transducer, except for the handle

 

 