MOX-1 MOX-2 MOX-3 MOX-4 Medical Oxygen O2 Gas Sensor

Price Negotiable
Price: Negotiable
MOQ: 1pcs
Delivery Time: 3-5 working days
Brand: City
Product Description

MOX-1 MOX-2 MOX-3 MOX-4 Mox1 Mox2 Mox3 Mox4 City Technology Medical Oxygen O2 Gas Sensor Original New.

 

 

MOX-1 MOX-2 MOX-3 MOX-4 oxygen sensors are designed to monitor partial pressure of oxygen in anesthesia (excluding xenon), intensive care, neonatal incubators, and general oxygen monitors.

MOX2 sensors come with adapters that fit onto the sensor threads and are used to direct airflow to the sensor.

 

MOX2 Oxygen Sensor

 

Test Gas % O2 Error
50% He / 50% O2 < 1%
60% N2 O / 40% O2 < 1%
2% Halothane / 40% O2 / 30% N2 0 / 5% CO2 / Bal N2 < 1.5%
2% Enflurane / 40% O2 / 30% N2 0 / 5% CO2 / Bal N2 < 1.5%
2% Isoflurane / 40% O2 / 30% N2 0 / 5% CO2 / Bal N2 < 1.5%

 

 

MOX2 Pictures

 

 

 

 

 

 

 

OEM # MOX-2
OEM City Technology
Condition New and original
Color White, Clear
Diameter 1.16 in
Humidity 0 to 99%
Measuring Range 0 to 100%
Power Requirements 9 to 13 mV Signal Output
Response Time 13 sec
Temperature Rating 0 to 45 Deg C

 

IMPORTANT: Connections can only be made with recommended mating parts.

Soldering to the sensor will damage it and void the warranty.

All performance data is based on cylinder gas measurements using a flow rate of 100 ml/min. Conditions were 20°C, 50% RH and 1013 mBar. For sensor performance data under other conditions, please contact City Tech.

Performance characteristics provide an overview of the performance of the sensors offered during the first 3 months. Over time, the output signal may drift below the lower limit.

 

 

Intended Use

 

These sensors are designed to monitor partial pressure of oxygen in anesthesia, intensive care, incubators, and general oxygen monitors.

 

Stabilisation time

Allow the instrument to stabilize for at least 15 minutes before calibration.

 

Cleaning and Disinfection

If the sensor is contaminated, it can be washed with distilled water and dried naturally. Sensors are not suitable for steam sterilization or exposure to chemicals such as ethylene oxide or hydrogen peroxide

 

 

Calibration interval

These sensors are designed to have minimal drift over their lifetime, but for maximum accuracy they should be calibrated in 100% oxygen prior to use.

 

 

FAQ :

 

1. Is the oxygen sensor expired?

We have expired and new date.

 

2.What’s your MOQ ?

Our MOQ is one piece .You can take one sample to check our quality .

 

3.Do you have price list or catalogue ?

As our stock is changing everyday ,it will be appreciated to check our website and send back pictures or part no to get price .

 

 

4.Can i have a discount ?

As our profit is very low ,if ordering more ,we can give you a discount .

 

 

If you have any interest in MOX-1 MOX-2 MOX-3 MOX-4 City Technology Medical Oxygen O2 gas sensor original new,feel free to contact us .Thank you .