DECG Reusable Legplate Adapter Cable REF 989803137651 LOT 101232 Direct ECG

Price Negotiable
Price: Negotiable
MOQ: Negotiable
Delivery Time: Negotiable
Brand: PHiliph
Product Description

PHiliphhilip DECG Reusable Legplate Adapter cable REF 989803137651 LOT 101232 Direct ECG

 

Brand Description:

 

PHiliphhilip, founded in the Netherlands in 1891, mainly produces lighting, home appliances, and medical systems. PHiliphhilip, with 128,100 employees worldwide in 2007, has production bases in 28 countries, sales offices in 150 countries, and has 80,000 patents.

 

Product description:

 

PHiliphhilip DECG Reusable Leplate Adapter Cable for 989803137631 & 989803137641 fetal spiral electrodes.it shown with Fetal Spiral Electrode and Attachment Electrode

 

 

Use with PHiliphhilip Healthcare Equipment as follows:

 

M2705A, M2703A, M1350A, M1350B, M1350C, M1353A, M1357A, M1364-60001, M2738A, M1365A, M2727A, M2735A, M2720A

 

DECG

 

Cleaning and Disinfecting:
For detailed instructions, refer to your Instructions for Use booklet.


Cleaning and Disinfection Schedule

 

The Legplate Adapter Cable exteriormust be cleaned after every use. Optionally, if you suspectthat the Legplate Adapter Cable’s internal cavity has become contaminated by fluids, you can alsoclean and disinfect the internal cavity.


Cleaning and disinfecting schedule

Required after every use As needed
• Clean and disinfect the Adapter Cable exterior • Clean the Adapter Cable’sinternal cavity
• Disinfect the Adapter Cable’sinternal cavity

 

Cleaning Agents and Disinfectants


Use only recommended cleaners and disinfectants listed below. Others may damage the LegplateAdapter Cable and shorten product lifetime or cause safety hazards

 

Recommended Cleaning Agents*

Tensides Alcohols
• Edisonite Schnellreiniger® • Ethanol 70-80%
• Isopropanol 70-80%
• Window Cleaner

 

 

Cautions


• Never sterilize the Legplate Adapter Cable by any means.


• You can immerse the patient end of the Legplate Adapter Cable, but nolonger than specified by the cleaning agent or disinfectant manufacturer.Do not immerse the Fetal Monitor connector.


• Select recommended cleaning agents and disinfectants carefully, becausesome products with similar names have different compositions.


• Always dilute cleaning agents and disinfectants according to manufacturers’instructions.


• Do not use strong oxidants or bleaches containing sodium hypochlorite(e.g. Clorox™).


• Do not use Povodine®, Sagrotan®, Mucocit®-P or strong organic solvents.• Do not use disinfectants containing iodine complexes.

 

FAQ

 

Q1 How can I pay for it?
A1 T/T,Western Union, PayPal are all acceptable.
Q2 What are your main brands?
A2 PHiliphhilip, Mindray, GE, NIHON KOHDEN, Goldway, etc.
Q3 How long will it take to receive the goods?
A3 It depends on your shipping address.
Q4 What will you do if you find any quality problems within the warranty period?
A4 Repair or replace according to the actual situation.