P/N 412341-001 Patient Monitor Parts GE Mainstream CO2 Reusable Adult Straight Airway Adapter

Price Negotiable
Price: Negotiable
MOQ: 1pcs
Delivery Time: 3-5 working days
Brand: GE
Product Description

P/N 412341-001 GE Mainstream CO2 Reusable Adult Straight Airway Adapter

 

 

The carbon dioxide function utilizes infrared light absorption technology to measure both excited and expired carbon dioxide and respiration rate. The patient monitor is connected to an external CapnoFlex low-flow lateral flow module or a novamet carbon dioxide III sensor connected to the airway adapter in the patient ventilation circuit. The circuitry that drives the sensor and processes its incoming signal resides within the DAS. Provides patient-adjustable upper and lower alarms for inhaled carbon dioxide, expired carbon dioxide, and breath rate. A patient alert for undetected breaths is also provided. Provides system alerts for various sensor conditions. Patient monitors accept connectors that are color coded in yellow

 

 

Part No Description Case Quantity
412341-001 Reusable adult straight airway adapter 1
415036-001 Disposable adult straight airway adapters 20
412343-002 Reusable straight airway adapter with tubing, male Luer locking connector and bed sheet clip 1
400149-002 Disposable straight airway adapters, female Luer Lock 150
405908-001 Disposable adult straight airway adapters 20
412342-001 Reusable neonatal straight airway adapter 1
415036-002 Disposable neonatal straight airway adapters; for monitoring neonatal patients with 4.0 mm or smaller endotracheal tubes 10

 

 

 

To calibrate the airway adapter, follow steps below :

1. Make sure the sensor is connected to the adapter.

2. Make sure the sensor cable is connected to the monitor CO2 patient port.

3. Make sure the airway adapter is clean and free of debris.

4. Place the sensor and adapter away from all sources of CO2, including the patient's ventilator exhalation, exhalation, and outlet valves.

5. Select the CO2 Parameters Window tab.

6. From the CO2 menu, select CalibrationAdapter.

7. Choose Ready. The "Calibration" message is displayed in the CO2 parameter window. When calibration is complete, the message will be cleared.

 

How to clean adapter

To clean the reusable adapter Wash with warm soap. and then immersed in a liquid disinfectant (Pasteurizer or cold sterilization) such as glutaraldehyde. Rinse with sterile water and dry.

To clean the adult dead zone adapter and low volume. Sterilize using ETO gas method or steam autoclave. Using a steam autoclave may shorten the life of the adapter.

Before reusing the adapter Make sure the sensor window is dry and free of debris. Also ensure that the adapter is not damaged during handling, cleaning, or disinfection.

 

FAQ:

 

  • How long is your warrranty ?

We offer 90 days warranty ,feel free to contact us for any questions .

  • How can i place order ?

Firstly ,contact us to confirm details ,then invoice will be sent to confirm .We will arrange the shipment in 3-5 working days after receiving payment

 

  • Can you ship as what we required ?

Sure ,we can.Shipping invoice will be sent to confirm before the shipment .

 

 

  • Do you have agent in my country?

No,we don't have right now.

 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company China World Technology Medical Equipment Service Group
Location TianHe District,GuangZhou,GuangDong
Contact Person Kiara

Request A Quote

Please check your email address.
Your message must be at least 20 characters.