| Items | Criteria | Test Method |
| Over-charge | No fire. No explosion. | Charging to 6V with Maximum Charging Current after Standard Discharge, then CV Charge till current decline to End-of-Charge Current or CV time is more than 7hours. |
| Short-Circuit | The maximum Temperature: ≤150℃. No fire. No explosion. | Rest for 30miniutes at (55±2)℃ after Standard Charge, then short-circuit battery by connecting the positive and negative terminals with a circuit load having a resistance load(copper wire) of 80±20mΩ.Test can be terminated when battery surface temperature has returned to ±10°C of environment temperature. |
| Thermal Abuse | No fire. No explosion. |
The battery is to be heated in a gravity convection or circulating air oven after Standard Charge. The temperature of the oven is to be raised at a rate of 5±2℃per minute to a temperature of 130 ±2°C and remain for 10 minutes. |
4.Reliability Characteristics
| Items | Criteria | Test Method |
| Static Humidity and Temperature | Retention Capacity:≥80%×CR Recoverable Capacity ≥85% ×CR No deformation. No rupture. No smoke. No leakage | After Standard Charge, the battery is stored at 40±2℃ and 90% -95%RH for 48hours, then rest for 2hours at 23±2 ℃ . Standard Discharge to test its retention capacity, and then perform a cycle with Standard Charge and Standard Discharge procedure to test recoverable capacity |
| Vibration | OCV≥3.6V No leakage. No fire. No explosion | After Standard Charge, the battery is fixed to vibration table and subjected to vibration cycling that the frequency is to be varied at the rate of 1Hz per minute between 10Hz and 55Hz, the excursion of the vibration is 1.6mm. The battery shall be vibrated for 30 minutes per axis of XYZ axes. |
| Drop | OCV≥3.6V No leakage. No fire. No explosion. | After Standard Charge, the battery is to be dropped from a height of 1 meter onto concrete board for 6 times, then measure Open Circuit Voltage. |
5.Charging-Discharging Temperature and Voltage, Current diagram
6.Application
7.Production Equipment
8.Our Service:
Customizations:dimension,capacity,protection board ,etc.
Quick Response:you requirements will be replied wihthin 12hours.
OEM are accepted.
Warranty: 13 months rarranty of products and goods after-sale service offered.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.