Product Description
General
Hospital IPS monitor system insulation monitor AIM-M10 with CE approval
Medical intelligent insulation monitoring instrument adopts advanced microcontroller technology, which has high integration,
compact size, convenient installation and integrates intelligence, digitalization and networking in one. It is ideal selection for
insulation monitoring of isolation power system in Class 2 medical locations such as operating room and intensive care unit.
Medical intelligent insulation monitoring instrument adopts advanced microcontroller technology, which has high integration,
compact size, convenient installation and integrates intelligence, digitalization and networking in one. It is ideal selection for
insulation monitoring of isolation power system in Class 2 medical locations such as operating room and intensive care unit.
Features
* real-time monitoring and fault alarming of the ground insulation resistance,
* transformer load current and transformer winding temperature of the monitored IT system,
* be used with insulation fault locator, remotely starting fault-locating and displaying locating results when there are
insulation faults,
* real-time monitor the line disconnection fault, temperature sensor disconnection fault and the functional grounding line
disconnection fault of the monitored system, and give the alarm indication within 2S after the fault occurs,
* relay alarm output, LED alarm indication and other faults indication functions,
* used for centralized alarm and display instrument, test signal generator, insulation fault locator and upper computer management
software communications, and can monitor the operation status of IT system in real time.
* Events logging function, which can record alarm occurrence time and fault type and is convenient for operation personnel to
analyze the operation conditions of system and promptly eliminate the faults.
* transformer load current and transformer winding temperature of the monitored IT system,
* be used with insulation fault locator, remotely starting fault-locating and displaying locating results when there are
insulation faults,
* real-time monitor the line disconnection fault, temperature sensor disconnection fault and the functional grounding line
disconnection fault of the monitored system, and give the alarm indication within 2S after the fault occurs,
* relay alarm output, LED alarm indication and other faults indication functions,
* used for centralized alarm and display instrument, test signal generator, insulation fault locator and upper computer management
software communications, and can monitor the operation status of IT system in real time.
* Events logging function, which can record alarm occurrence time and fault type and is convenient for operation personnel to
analyze the operation conditions of system and promptly eliminate the faults.
Technical parameters
| Model | AIM-M10 | AIM-M100 | AIM-M200 | |
| Power supply | Voltage | AC220V±10% | AC220V±10% | DC24V±25% |
| Frequency | 50/60Hz | 50/60Hz | - | |
| Max power consumption | <5W | <8W | <3W | |
| Insulation monitoring | Insulation resistance measuring range | 10-999kΩ | ||
| Relative percentage accuracy | 0—±10% | |||
| Alarm value range | 10—995kΩ | 50—999kΩ | 50—999kΩ | |
| Response time | <2s | |||
| Measuring voltage | <12V | |||
| Measuring current | <42uA | <50uA | <50uA | |
| Current monitoring | Measuring range | 2.1-50A | ||
| Alamm value range | 5-50A | |||
| Measurement accuracy | ≤±5% | |||
| Temperature monitoring | Thermal resistor | PT100 | ||
| Measuring range | -50—+200℃ | |||
| Alarm value range | 0—+200℃ | |||
| Alarm output | Output type | 1 channel relay output | 2 channels relay output(programmable) | 2 channels relay output |
| Contact rating |
AC 250V/3A DC 30V/3A |
AC 250V/3A DC 30V/3A |
AC 250V/3A DC 30V/3A | |
| Environment | Working temperature | -10—+55℃ | ||
| Storage temperature | -20—+70℃ | |||
| Relative humidity | 5%-95%,non-condensing | |||
| Altitude | ≤2500m | |||
| Communication | RS485 interface,Modbus-RTU protocol | RS485 interface,Modbus-RTU protocol |
CAN interface, custom protocol, RS485 interface, Modbus-RTU protocol |
|
Dimension

Wiring

Typical connection



Similar Products
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Jiangsu Acrel Electrical Manufacturing Co., LTD.
Location
No. 9 Xincheng Road,Chengjiang Street, Jiangyin City, Jiangsu Province,China
Contact Person
Dina Huang