Sichuan Xincheng Biological Co., Ltd.
                                                                                                           
Verified Supplier
19 Years
Since 2007
Menu

100pcs Serum Amyloid A sAA Rapid Test Kits CE Approved For Blood

Price Negotiable
Price: USD2.0-USD3.5 test
MOQ: 10,000tests
Delivery Time: 3-5 working days
Brand: Diagence
Product Description

Serum Amyloid A Inflammation Test Kit CE Approved With 100Tests/Box

 

 

What are the advantages?

 

² Fast: 4 Minutes

² Convenient: human serum, human plasma, and human whole blood samples

² Cheap: Lower cost with high efficiency

 

Summary

 

SAA is a human acute phase protein, which is a normal component present at low levels in the blood. It rises quickly when the human body has bacterial or viral infectious inflammation, active disease, or large-scale tissue damage. In the acute phase of inflammation or infection ( 48h~72h) can increase rapidly, and decrease rapidly during the recovery period of the disease. Studies have shown that elevated serum SAA can be detected in diseases such as bacteria, fungi, viral infections, atherosclerosis, cardiovascular disease, and acute transplant rejection. Similar to C-reactive protein, SAA helps diagnose inflammation and evaluate its therapeutic effects. However, in some diseases, such as viral infections, cardiovascular diseases, transplant rejection, etc., SAA can be more sensitive than C-reactive protein, and can be Clinical diagnosis provides better reference value. Combined detection of C-reactive protein and SAA can improve the sensitivity of the diagnosis of infection.

Commonly used detection methods include immunoturbidimetric method, enzyme-linked immunosorbent assay, immunofluorescence chromatography, chemiluminescence method, etc.

 

 

Test Principle

 

This reagent forms a double-antibody sandwich complex with SAA and is equipped with a fluorescence detector to detect the concentration of SAA in serum, plasma and whole blood. After the sample to be tested is evenly mixed with the buffer, it is added dropwise to the sample hole of the test card. The sample reacts with the fluorescently labeled SAA mouse anti-human monoclonal antibody coated on the sample pad to form an antigen-antibody complex, which is then chromatographed to nitrocellulose On the plain membrane, it reacts specifically with the coated SAA mouse anti-human monoclonal antibody and is captured. The amount of captured fluorescent complex is positively correlated with the concentration of SAA in the sample. The fluorescence intensity is detected and converted to the SAA concentration according to the calibration curve calibrated on the ID chip or test card.

 

Limitation

Anti-interference ability Anti-interference ability: When cholesterol ≤15mg/ml, bilirubin ≤2mg/ml, triglyceride ≤30mg/ml, there is no obvious influence on the test results.

 

Performance characteristics

  • Linear range: 0.5mg/L~100.0mg/L, take the same batch of SAA reagent to the concentration of 0.0mg/L, 5.0mg/L, 25.0mg/L, 50.0mg/L, 100.0mg/L Serum amyloid A samples were tested, and the correlation coefficient was r≥0.9900.
  • Precision: intra-assay precision CV≤15.0%, inter-assay relative deviation R≤15.0%.
  • Accuracy:The Relative Deviation is within ±15.0%.
  • Blank limit: should not exceed 0.10ng/ml.

Precautions and warnings

 

1. This product is only used for in vitro diagnosis.

2. This reagent contains animal-derived ingredients, and its biological safety complies with the regulations, but it is still treated as a potentially dangerous substance.

3. The reagent contains chemical components. Avoid eating or touching the skin and mucous membranes. If you accidentally splash the reagent into your eyes, please rinse with plenty of water immediately, and seek medical attention if necessary.

4. The samples and waste liquid generated after testing should be treated as the source of infection, and the packaging materials after use should be treated in accordance with relevant regulations.

5. Do not insert the test card whose surface is wetted by other liquids into the detector, otherwise it may cause contamination or damage to the instrument.

6. The batch number of the test card, the batch number of the buffer solution and the batch number on the ID chip should be consistent, otherwise the test results may be inaccurate.

7. If the kit is stored for a long time, it is recommended to store it at 2℃~8℃.

8. See the label for the production date and expiry date.

 

Product Name Storage Packing Approved
Serum Amyloid A Assay Kit 2℃~30℃ 100Tests/Box CE

 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Sichuan Xincheng Biological Co., Ltd.
Location No. 101 Tianxin Road, High-Tech West Zone, Chengdu, Sichuan Province, China

Request A Quote

Please check your email address.
Your message must be at least 20 characters.