1250-1500gpm Split Casing Fire Fighting Water Pump FM UL standards

Price Negotiable
Price: Negotiated
MOQ: 1 pcs
Delivery Time: 45 working days
Brand: SANCHANG
Product Description

Double Suction Split Case Fire Fighting Water Pump COS-F125-290 (1250-1500gpm 80-120m)

 

Description

A fire fighting water pump is a centrifugal pump which is used for pumping fire-fighting water. Fire-fighting pumps can be designed for transportable use (e. g. on fire-fighting vehicles or as portable fire pumps) or for stationary use (e. g. hydrants, sprinkler systems).

 

The XSF series Horizontal Split Case Fire Fighting Water Pumps are engineered for reliable operation upon stationary use. All fabricated parts are standardized and accurately machined for true alignment, increasing overall durability. Precision balancing of all rotating components provides mechanical dependability, reliable operation and minimal maintenance. Impellers are constructed with double inlets that practically eliminated end thrust while boosting operating efficiency.

 

Stationary fire-fighting pump
The most important and most common fire-fighting systems are sprinkler systems. Sprinkler systems consist of several sprinkler heads which are connected via a piping system. Large heat automatically triggers the sprinkler heads in defined intervals to protect the rooms they are installed in.
 Sprinkler systems are automatic fire-fighting systems.

 

Fire hydrants are another type of fire-fighting system. Hydrants are activated manually. Depending on their type they are either designed for general use or for activation by fire-fighters only.

 

Wet-pipe sprinkler systems are the most common type of sprinkler system. In this system, the pipelines are permanently under pressure and filled with water. The fire-fighting water will be discharged immediately as soon as one or several sprinklers have been activated. In dry-pipe sprinkler systems pipelines laid in areas which are likely to be effected by frost/freezing are filled with air.

 

Depending on the hazard class, sprinkler systems may be required to be supplied with water from two independent sources, using either one or two fire-fighting pumps. If two pumps are used, two independent energy sources may have to be provided, depending on the applicable regulations.

Features
* Exceptional hydraulic efficiencies
* Double entry reduce end thrust force, increase efficiency and bearing life
* Stainless steel impellers and shaft as standard
* Reduced efficiency degradation
* Comply to FM and/or UL standards (NFPA 20, UL448 and FM1311)


Parameters of COS-F series Split Case Fire Fighting Water Pump

Flow Capacity 1250-1500 gpm Delivery Head 80-120 m
Inlet/Outlet Dia. DN200/DN125 mm Working Pressure ≤ 1.8 MPa
Liquid Temperature 0 - 80 ℃ Driven By Electric Motor / Diesel Engine
Seal Type Mechanical seal / Gland packing Liquid  Clean water or similar
Material of Construction  Cast Iron / Cast Steel / S.S304 / S.S316 / Duplex S.S2205

 

 

Main Parts Configuration

To meet the NFPA20 standards, the pump was constructed with the following materials:

Parts Name Material of Construction (Comply with NFPA20)
Pump Case Ductile Iron
Shaft 40Cr / 35CrMo / 42CrMo/S.S420
Shaft Sleeve S.S304
Impeller S.S304/Bronze
Wearing Ring S.S304/Bronze
Bearing China Make/NSK/SKF
Seals PTFE Packing Seals/Mechanical Seals

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company CHANGSHA SANCHANG PUMP CO., LTD.
Location No.517, Xiangfu Rd(E), Yuhua District, Changsha City, Hunan Province, P.R. China
Contact Person Johnson

Request A Quote

Please check your email address.
Your message must be at least 20 characters.