Product Description
X20PS9400 B&R 24VDC Supply Module For Bus Controller, X2X Link Power Supply And I/O
MATERIAL NUMBER:
X20PS9400
DESCRIPTION:
- Supply for the bus controller, X2X Link and internal I/O supply
- Feed and bus controller / X2X Link supply electrically isolated
- Redundancy of bus controller / X2X Link supply possible by operating multiple supply modules simultaneously
- Service interface (RS232)
The supply module is used together with an X20 bus controller. It is equipped with a feed for the bus controller, the X2X Link and the internal I/O supply.
Short description
| Power supply module | 24 VDC supply module for bus controller, X2X Link power supply and I/O |
| Interfaces | 1x RS232 service interface |
General information
| B&R ID code | 0x1F8C |
| Status indicators | Overload, operating status, module status, RS232 |
| Diagnostics | |
| Module run/error | Yes, using LED status indicator and software |
| RS232 data transfer | Yes, using LED status indicator |
| Overload | Yes, using LED status indicator and software |
| Power consumption for X2X Link power supply | 1.42 W |
| Power consumption | |
| Internal I/O | 0.6 W |
| Additional power dissipation caused by actuators (resistive) [W] | - |
| Certifications | |
| CE | Yes |
| UKCA | Yes |
| ATEX | Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X |
| UL | cULus E115267 Industrial control equipment |
| HazLoc | cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5 |
| DNV | Temperature: B(0 - 55°C) Humidity: B(up to 100%) Vibration: B(4 g) EMC: B(bridge and open deck) |
| LR | ENV1 |
| KR | Yes |
| ABS | Yes |
| EAC | Yes |
| KC | Yes |
Bus controller / X2X Link power supply input
| Input voltage | 24 VDC -15% / +20% |
| Input current | Max. 0.7 A |
| Fuse | Integrated, cannot be replaced |
| Reverse polarity protection | Yes |
Bus controller / X2X Link power supply output
| Nominal output power | 7 W |
| Parallel connection | Yes |
| Redundant operation | Yes |
| Overload characteristics | Short-circuit proof, temporary overload |
Input I/O power supply
| Input voltage | 24 VDC -15% / +20% |
| Fuse | Required line fuse: Max. 10 A, slow-blow |
| Reverse polarity protection | No |
Output I/O power supply
| Nominal output voltage | 24 VDC |
| Behavior on short circuit | Required line fuse |
| Permissible contact load | 10 A |
Interfaces
| Service interface | |
| Signal | RS232 |
| Variant | Connection made using 12-pin terminal block X20TB12 |
| Max. transfer rate | 115.2 kbit/s |
Electrical properties
| Electrical isolation |
BC/X2X Link supply isolated from BC/X2X Link power supply
I/O supply not isolated from I/O power supply, and RS232 not isolated from bus
|
Operating conditions
| Mounting orientation | |
| Horizontal | Yes |
| Vertical | Yes |
| Installation elevation above sea level | |
| 0 to 2000 m | No limitation |
| >2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature | |
| Operation | |
| Horizontal mounting orientation | -25 to 60°C |
| Vertical mounting orientation | -25 to 50°C |
| Derating | See section "Derating". |
| Storage | -40 to 85°C |
| Transport | -40 to 85°C |
| Relative humidity | |
| Operation | 5 to 95%, non-condensing |
| Storage | 5 to 95%, non-condensing |
| Transport | 5 to 95%, non-condensing |
Mechanical properties
| Note | Order 1x terminal block X20TB12 separately. Order 1x bus base X20BB8x separately. |
| Pitch | 12.5+0.2mm |