Temperature, Humidity, and Low Pressure Test Chamber Electronics and Electrical Components
Temperature, Humidity, and Low Pressure Test Chamber
A Temperature, Humidity, and Low Pressure Test Chamber is designed to simulate harsh environmental conditions by testing the combined effects of extreme temperatures, humidity, and low atmospheric pressure on products, materials, and components. This chamber helps to evaluate how items perform under extreme conditions that may occur during their transportation, storage, or use, especially at high altitudes or in space-like environments. The chamber’s ability to control temperature, humidity, and pressure allows for comprehensive testing to ensure the durability, reliability, and safety of various products.
Key Features:
- Temperature Control: The chamber offers precise temperature regulation, ranging from very low to high temperatures, allowing users to simulate diverse environmental conditions.
- Humidity Control: It features a high-precision humidity system to control both high and low relative humidity levels, testing the moisture resistance of materials and products.
- Low-Pressure Simulation: The chamber can simulate low atmospheric pressure, similar to that found at high altitudes or in aerospace applications, to test how products withstand changes in pressure and air density.
- Programmable Control: Users can program specific test cycles with custom temperature, humidity, and pressure parameters to replicate real-world scenarios.
- Advanced Safety Features: Equipped with over-temperature, over-humidity, and pressure monitoring systems to ensure safe and reliable operation.
- Uniform Environmental Distribution: Ensures consistent environmental conditions throughout the testing chamber for accurate and repeatable results.
Applications:
- Aerospace and Aviation: Widely used in aerospace for testing components like sensors, electronic devices, and materials, simulating conditions experienced during flight at high altitudes and space missions.
- Automotive Industry: Tests the performance of automotive parts (such as sensors, electrical systems, and seals) under extreme weather, altitude, and pressure conditions, ensuring their durability and reliability.
- Electronics and Electrical Components: Essential for testing the durability of electrical equipment, such as circuit boards, batteries, and semiconductor devices, under high/low temperatures, humidity, and low-pressure environments.
- Military and Defense: Used for evaluating equipment like communication systems, navigation instruments, and protective gear, ensuring they perform in extreme weather and pressure conditions.
- Medical Devices: Assists in testing medical equipment and devices, ensuring they function correctly under a range of environmental conditions that may be encountered in high-altitude or extreme climates.
- Consumer Goods Testing: For products like outdoor equipment, sporting goods, and packaging, it ensures reliability under environmental extremes during use or transport.
- Pharmaceutical and Food Industry: Testing packaging materials, medications, and food products for durability and stability in varying environmental conditions
Specifications
| Temperature Chambers Climate Chambers | ETQ7025 | ETQ7050 | ETQ7100 | ETQ7200 |
| ECQ7025 | ECQ7050 | ECQ7100 | ECQ7200 | |
| Test Space Volume (L) | 250 | 500 | 1000 | 2000 |
| Temp. Test Parameters: | ||||
| Temp. Range (℃) | -70~+150 | |||
| Temp.Constancy (℃) | ±1.0 ~ ±0.8 (Atmospheric Pressure No Load) | |||
| Temp. Homogeneity (℃) | ±0.5 ~ ±2.0 (Atmospheric Pressure No Load) | |||
| Temp. Accuracy (℃) | ±2.0 (Atmospheric Pressure No Load) | |||
| Heat Up Time (min) (+20℃ to~150℃) | 60 | 60 | 50 | 60 |
| Cooling Down Time (min) (+20℃ to~60℃) | 90 | 80 | 60 | 80 |
| Pressure Range (Kpa) | Atmospheric Pressure~ 1.0 Atmospheric Pressure ~ 0.5 | |||
| Pressure Accuracy (Kpa) | ±2.0 (Atmospheric Pressure~ 40Kpa);±5%(40KPa~4KPa);±0.1(4KPa~1KPa) | |||
| Pressure Release Time (min) | 45(Atmospheric Pressure→1KPa) | |||
| Rapid Release of Pressure Function (Optional) | Pressure Release Range:75.2KPa →18.8KPa; Pressure Release Time:15sec | |||
| Climate Test Parameters for ECQ series: | ||||
| Temp. Range (℃) | +10 ~ +95 | |||
| Temp. Constancy (℃) | ±1.0 ~ ±0.8 (Atmospheric Pressure No Load) | |||
| Temp. Homogeneity (℃) | ±1.0 ~ ±2.0 (Atmospheric Pressure No Load) | |||
| Humid. Range (%RH) | (10) 20 ~ 98 (Atmospheric Pressure No Load) | |||
| Humid. Constancy (%RH) | ±1.0 - ±3.0 (Atmospheric Pressure No Load) | |||
| Test Space Dimension (mm) | 600W×600D×700H | 800W*700D*900H | 1000W×1000D×1000H | 1400W*1200D*1200H |
| External Dimension (mm) | 1000W×1800D×1800H | 1500W*2750D*1900H | 1400W×3250D×2000H | 1810W*3710D*2310H |
| Power | AC380V±10%,50HZ,3/N/PE | |||
| Cooling Methods | Water-Cooled | |||
| Options | Standard Version |
| ☆ APP for mobility management | ☆ 1 Set testing electrode |
| ☆ Independent sensors for specimen protection (NE60519-2.1993) | ☆ Electronic temperature and humidity sensors |
| ☆ 1 Entry port Φ50mm | |
| ☆ Nitrogen gas auxiliary device | |
| ☆ Spare parts package | |
| ☆ E-management and cyber-software | |
| ☆ Rapid release of pressure device | |
| ☆ Video monitor system | |
| ☆ Rapid recovered pressure device |