600L Multi-Purpose 180 Degree Temperature Humidity Test Chamber for Comprehensive Testing
Mobile Phone Temperature And Humidity Test Chamber Phone Charger Test Equipment
Temperature and humidity test chamber for material temperature resistance and product testing can be used when constant climate conditions (temperature and/or humidity) are needed for product testing. It also can be used for a variety of materials of high - low temperature alternating test. The test temperature, humidity, time can be programmed. Provides conditions of temperature from -42
to +18 0degree and of humidity from 10% to 98%.
|
|
|
|
|
|
|
|
|
|
energy saving and rapid heating/cooling rate |
|
|
|
| Model: Temperature And Humidity Test Chamber | EC4060 |
| Test Space Volume(L) | 600 |
| Temperature Test Parameters: | |
| Temp. Range (℃) | -45/+180 |
|
Temp. Constancy (℃) |
±0.1-±0.5 |
| Temp. Homogeneity (℃) |
±0.5-±2.0 |
| Heating Rate(℃/min) | 4.0 |
| Cooling Rate (℃/min) | 3.0 |
|
Temp. Max. Thermal Compensation (W) |
1500 |
| Climate Test Parameters: | |
| Dewpoint Temp.Range (℃) |
+4(-3)-+94 |
| Humid. Range (%RH) | 10-98 |
| Humid.Constancy (%RH) | ±1.0-±3 |
| Temp. Constancy (℃) | ±0.1-±0.3 |
| Temp. Homogeneity (℃) | ±0.5-±2.0 |
| Temp and Humid Max.Thermal Compensation (W) |
500 |
| Power | AC380V±10%,50HZ,3/N/PE |
|
Optional Accessories: Independent sensors for specimen protection(NE60519-2.1993) 1 Entry port Φ100mm Drier filter for compressing air Automatic water supply device Nitrogen gas auxiliary device Water-Cooled unit Spare parts package E-management and cyber software Video monitor system APP for mobility management |
Standard Version: 3 Power outlets for specimens Left and right entry ports Φ50mm Silicon Stoppers for entry ports 2 Stainless steel shelves 1 Water tank with 20L 1 Water filter |
- The temperature and humidity test chamber is based on the balanced temperature and humidity control system.Temperature and humidity measured by the chamber temperature and humidity sensor input and output by the A / D converter temperature and humidity control, temperature and humidity control algorithm through the internal comparison algorithm output command driven I / O port, the air supply system, refrigeration system, heating System, humidification system, dehumidification system to coordinate work.
- The main controller accurately controls the temperature and humidity output of each subsystem through the software algorithm. The temperature, humidity and humidity of the subsystem are evenly distributed through the specially designed circulating air supply system, so that the humidity Heat loss continued to be compensated to achieve the level of constant temperature and humidity control.

Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.