Sinuo Testing Equipment Co. , Limited
                                                                                                           
Verified Supplier
7 Years
Since 2019
Menu

IEC 62916-3 EV Plug and Socket Temperature Rising Test System 6500A

Price Negotiable
Price: Negotiable
MOQ: 1
Delivery Time: 30 Days
Brand: Sinuo
Product Description

 
 

IEC 62916-3 EV Plug and Socket Temperature Rising Test System 6500A
 
Complied Standards & Clauses


 
This advanced test system is designed in compliance with IEC 62196-1 Ed.4 CDV 2020 (clause 12.3, clause 24, table 10, clause 34.2, 34.4, and 35.4), IEC 62916-2, IEC 62916-3, and other relevant standards.
 
Product Overview


 
This system is primarily used to assess the temperature rise of electric vehicle plugs and sockets at rated current and to check surface heating of electrical accessories during load connection. It also supports short-duration, high-current withstand testing of ground contacts, ensuring reliable performance and safety verification.
Equipped with proprietary software and computer control, the system enables fully automated test execution and data analysis. Its intuitive operation and precise performance provide an efficient solution for temperature rise assessment and compliance verification of electric vehicle charging interfaces and related components.
 

Technical Parameters


 

Output Workstation 1 DC output station
Maximum Output Voltage DC less than DC 15V
Constant Adjustable Test Current Output DC 200–6500A
Current Display Accuracy

±(0.25% of reading + 0.25% of range), resolution 1A

Voltage Display Accuracy

±(0.25% of reading + 0.25% of range), resolution 0.01V

Test Current Stability

±(1% of set value + 0.5A), response time approximately 1s

Control Contact Power Supply

Current range AC (0–2) A

Operating Modes

Continuous mode, On/Off mode, Automatic temperature control mode

Continuous On/Off Mode

1. Continuous Mode Test Time: 0.01–99.99 hours
2. On/Off Mode Power On/Off Time: 0.01–99.99 hours
3.On/Off Count: 1–9999 times, stops automatically when the count is reached
4.Current Setting: Programmable control settings (can be configured according to IEC62196, with time and current combinations as shown in the table below)

Automatic Temperature Control Mode

The system can set a stable temperature rise value and automatically find the appropriate current value.
• Temperature Rise Setting Range: 0–100°C
• Stability Accuracy: ±0.5°C
• Automatically calculates the required current for the desired temperature rise

Voltage Display Accuracy ±(0.25% of reading + 0.25% of range), resolution 0.01V
Temperature Measurement Range

0–260°C, Accuracy: ±0.3% of reading + 1°C; Resolution: 0.1°C

Temperature Measurement Points

16 channels (including 1 point for measuring ambient temperature)

Thermocouple Types Supported

The instrument supports J, K, T, E, S, N, B, R types of thermocouples.

Thermocouple Used for Measurement

USA Ω Company K-type 30AWG fine wire thermocouples, length 2 meters, 20 pieces in total

Control Contact Power Supply Current range AC (0–2) A
Operating Modes Continuous mode, On/Off mode, Automatic temperature control mode
Test Current Stability

±(1% of set value + 0.5A), response time approximately 1s

Current Display Accuracy ±(0.25% of reading + 0.25% of range), resolution 1A

 

Details


 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Sinuo Testing Equipment Co. , Limited
Location Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone, Shibi Street, Panyu District, Guangzhou, China
Contact Person Zoe Zou

Request A Quote

Please check your email address.
Your message must be at least 20 characters.