Submersible Solar Water Pump Inverter Single Phase VFD 0.75KW To 710KW
Submersible Solar Water Pump Inverter Single Phase VFD 0.75KW To 710KW
VEIKONG Solar Water Pump Inverter Single Phase Three Phase 0.75KW - 710KW
VEIKONG is professional manufacturer of solar pump inverter, variable frequency dirve, soft starter.
Electrical Specifications and Power degree
| 220V | 380V | |
| Max input DC voltage | 450V | 810V |
| DC voltage range | 150~450VDC | 300~810VDC |
| Normal working DC voltage | 260V-400V | 400V-650V |
| Recommended input mppt voltage | 330V | 550V |
| MPPT efficiency | >99% | |
| Rated output voltage | 1/3-phase 220VAC | 3-phase 380-480VAC |
| Output frequency range | 50/60Hz | |
| Max efficiency of the machine | 99% | |
| Power range | 220v 0.75kw to 75kw, 380v 1.5kw-160kw | |
| Cooling method | Air cooling | |
| Protection degree | IP20/IP65 | |
| Altitude | Below 1000m; above 1% for every additional 100m. | |
| Standard | CE/ROHS | |
Noted: We suggest solar panel power should be 1.3-1.4 times higher than solar pump power ,
And solar pump inverter power should be higher level than solar pump.
When solar pump distance to inverter higher than 100m,
It should be equipped with Output reactor or higher level power inverter.
For Solar panel,total VOC less than Maximum DC voltage of inverter and Solar panel vmp is recommend
530V for 380V pump and 305V for 220V pump.
VEIKONG VFD500-PV solar pump inverter Features:
Protection features
- Protection features : Electronic monitoring gives the controller the capability to monitor the system and automatically shut down in the even of: Dry run conditions- with smart pump monitoring, High voltage surge, Low input voltage, Open motor circuit, Short circuit, Over heat, Earth fault, Phase missing
- Dry protection : If no water in the ground, the water pump will stop working automaticallly and when the water comes, starts to working automatically.
- Automatic working: When the sunshine not good then pumps slow down automatically and when sunline become good then go on working.
- Save cost/directly connect solar panel: Solar panel connects solar inverter directly and to the pump. Also control the water level in the tank. No enough water in the tank working fast, enough water will stop working automatically. (how much water you need, you can set parameters)
- Speed & frequency control, No need battery: 0-320hz output by Vector control/0-3200hz output by VF control. No need battery in system.
Mode Range
| Drive model | Max DC input current (A) | Rated output current (A) | Applicable water pump (kW) |
| VFD500M-40T00150-PV | 6.1 | 3.7 | 1.5 |
| VFD500M-40T00220-PV | 7.1 | 5 | 2.2 |
| VFD500M-40T00400-PV | 16.5 | 9.4 | 4 |
| VFD500M-40T00550-PV | 23.9 | 13 | 5.5 |
| VFD500M-40T00750-PV | 30.6 | 17 | 7.5 |
| VFD500-40T00150-PV | 6.1 | 3.7 | 1.5 |
| VFD500-40T00220-PV | 7.1 | 5 | 2.2 |
| VFD500-40T00400-PV | 16.5 | 9.4 | 4 |
| VFD500-40T00550-PV | 23.9 | 13 | 5.5 |
| VFD500-40T00750-PV | 30.6 | 17 | 7.5 |
| VFD50040T01100-PV | 39.2 | 25 | 11 |
| VFD500-40T01500-PV | 49.0 | 32 | 15 |
| VFD500-40T01850-PV | 57 | 37 | 18.5 |
| VFD500-40T02200-PV | 69 | 45 | 22 |
| VFD500-40T03000-PV | 91 | 60 | 30 |
| VFD500-40T03700-PV | 114 | 75 | 37 |
| VFD500-40T04500-PV | 146 | 90 | 45 |
| VFD500-40T05500-PV | 190 | 112 | 55 |
| VFD500-40T07500-PV | 237 | 152 | 75 |
| VFD500-40T09000-PV | 273 | 176 | 90 |
| VFD500-40T11000-PV | 319 | 210 | 110 |
| VFD500-40T13200-PV | 389 | 253 | 132 |
| 220V single phase or three phase level | |||
| VFD500-20T00075-PV | 6.7 | 4.5 | 0.75 |
| VFD500-20T00150-PV | 9.9 | 7 | 1.5 |
| VFD500-20T00220-PV | 14.1 | 10.6 | 2.2 |
| VFD500-20T00400-PV | 22.6 | 17 | 4 |
| VFD500M-20T00150-PV | 9.9 | 7 | 1.5 |
| VFD500M-20T00220-PV | 14.1 | 10.6 | 2.2 |


For 220V single phase motor connection
1: Single phase asynchronous motor wiring method (without starting capacitor):
Notice: U is connected to the common end of the starting winding and the working winding, V is connected to the starting winding, and W is connected to the working winding;
Single-phase asynchronous motor if the rotary steering is not correct, you can change the V and W wiring or set P22.13=1.
First solution: Set parameter P11.01=1 (Single phase motor type without capacitor) or second solution: set P00.11=31 if your motor frequency is 50 hz or set P00.11=32 if your motor frequency is 60HZ