Shenzhen Veikong Electric Co., Ltd.
                                                                                                           
Verified Supplier
13 Years
Since 2013
Menu

Submersible Solar Water Pump Inverter Single Phase VFD 0.75KW To 710KW

Price Negotiable
Price: Negotiable
MOQ: 1
Delivery Time: 3 days, depend on the order quantity
Brand: VEIKONG
Product Description

Submersible Solar Water Pump Inverter Single Phase VFD 0.75KW To 710KW​

 

VEIKONG Solar Water Pump Inverter Single Phase Three Phase 0.75KW - 710KW

 

VEIKONG is professional manufacturer of solar pump inverter, variable frequency dirve, soft starter.

 

 

Electrical Specifications and Power degree

 

  220V 380V
Max input DC voltage 450V 810V
DC voltage range 150~450VDC 300~810VDC
Normal working DC voltage 260V-400V 400V-650V
Recommended input mppt voltage 330V 550V
MPPT efficiency >99%
Rated output voltage 1/3-phase 220VAC 3-phase 380-480VAC
Output frequency range 50/60Hz
Max efficiency of the machine 99%
Power range 220v 0.75kw to 75kw, 380v 1.5kw-160kw
Cooling method Air cooling
Protection degree IP20/IP65
Altitude Below 1000m; above 1% for every additional 100m.
Standard CE/ROHS

 

Noted: We suggest solar panel power should be 1.3-1.4 times higher than solar pump power ,

And solar pump inverter power should be higher level than solar pump.

When solar pump distance to inverter higher than 100m,

It should be equipped with Output reactor or higher level power inverter.

For Solar panel,total VOC less than Maximum DC voltage of inverter and Solar panel vmp is recommend

530V for 380V pump and 305V for 220V pump.

 

 

VEIKONG VFD500-PV solar pump inverter Features:

 

Protection features

  • Protection features : Electronic monitoring gives the controller the capability to monitor the system and automatically shut down in the even of: Dry run conditions- with smart pump monitoring, High voltage surge, Low input voltage, Open motor circuit, Short circuit, Over heat, Earth fault, Phase missing
  • Dry protection : If no water in the ground, the water pump will stop working automaticallly and when the water comes, starts to working automatically.
  • Automatic working: When the sunshine not good then pumps slow down automatically and when sunline become good then go on working.
  • Save cost/directly connect solar panel: Solar panel connects solar inverter directly and to the pump. Also control the water level in the tank. No enough water in the tank working fast, enough water will stop working automatically. (how much water you need, you can set parameters)
  • Speed & frequency control, No need battery: 0-320hz output by Vector control/0-3200hz output by VF control. No need battery in system.
 

 

Mode Range

 

Drive model

Max DC input current (A)

Rated output current (A)

Applicable water pump (kW)

VFD500M-40T00150-PV

6.1

3.7

1.5

VFD500M-40T00220-PV

7.1

5

2.2

VFD500M-40T00400-PV

16.5

9.4

4

VFD500M-40T00550-PV

23.9

13

5.5

VFD500M-40T00750-PV

30.6

17

7.5

VFD500-40T00150-PV

6.1

3.7

1.5

VFD500-40T00220-PV

7.1

5

2.2

VFD500-40T00400-PV

16.5

9.4

4

VFD500-40T00550-PV

23.9

13

5.5

VFD500-40T00750-PV

30.6

17

7.5

VFD50040T01100-PV

39.2

25

11

VFD500-40T01500-PV

49.0

32

15

VFD500-40T01850-PV

57

37

18.5

VFD500-40T02200-PV

69

45

22

VFD500-40T03000-PV

91

60

30

VFD500-40T03700-PV

114

75

37

VFD500-40T04500-PV

146

90

45

VFD500-40T05500-PV

190

112

55

VFD500-40T07500-PV

237

152

75

VFD500-40T09000-PV

273

176

90

VFD500-40T11000-PV

319

210

110

VFD500-40T13200-PV

389

253

132

220V single phase or three phase level

VFD500-20T00075-PV

6.7

4.5

0.75

VFD500-20T00150-PV

9.9

7

1.5

VFD500-20T00220-PV

14.1

10.6

2.2

VFD500-20T00400-PV

22.6

17

4

VFD500M-20T00150-PV

9.9

7

1.5

VFD500M-20T00220-PV

14.1

10.6

2.2

 

Product Application

 
 

For 220V single phase motor connection

1: Single phase asynchronous motor wiring method (without starting capacitor):

Notice: U is connected to the common end of the starting winding and the working winding, V is connected to the starting winding, and W is connected to the working winding;

 

Single-phase asynchronous motor if the rotary steering is not correct, you can change the V and W wiring or set P22.13=1.

 

First solution: Set parameter P11.01=1 (Single phase motor type without capacitor) or second solution: set P00.11=31 if your motor frequency is 50 hz or set P00.11=32 if your motor frequency is 60HZ

 

For 220V single phase motor connection

2: Single-phase asynchronous motor wiring method (with capacitor)

 

Notice1: First solution: Connect motor cable to power terminal U and V and enter BSC mode to Set parameter P23.15=0(output phase loss shielding protection) or second solution: set macro P00.11=21 if your motor frequency is 50HZ or set P00.11=22 if your motor frequency is 60HZ

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Shenzhen Veikong Electric Co., Ltd.
Location 4F, Building 5, Dongluyang Industrial ,Park, No. 4, Tengfeng 4th Road, Fuyong Phoenix Third, Industrial Zone, Baoan District, Shenzhen China
Contact Person Terry

Request A Quote

Please check your email address.
Your message must be at least 20 characters.