Laboratory Chemical Ductless Fume Hood Acid And Alkali Resistant

Price Negotiable
Price: Negotiable
MOQ: Negotiable
Delivery Time: Negotiable
Product Description

Acid And Alkali Resistant Laboratory Chemical Ductless Fume Hood

Product Description


A ductless fume hood is contained ventilation equipment or working space that filters out chemical airborne materials and recycles them back to the working environment as breathable air. It uses activated carbon filters to clean the fumes. Ductless fume hoods usually have a frontal airflow to get the air out at a controlled rate to prevent the harmful gases from going out of the workstation.

There are two filters in a ductless fume hood - the pre-filter and the main filter. Both of them work to remove the contaminants in the fumes. It starts with the ambient air going into the ventilation hood with the gases or vapors produced during the laboratory work. The air in the hood goes through the pre-filter, where some of the impurities are sifted.

Once it has gone through the pre-filter, it goes through the main filters, where other particulates are thoroughly removed. Then, the air goes out from the main filter to the workstation as breathable air.

Product Parameters

 

                Model Specification   WJ-1500A WJ-1500B WJ-1800A WJ-1800B
External dimensions of equipment(mm) 1500(W)*1205 (D) *2400 (H) 1800(W)*1205 (D) *2400 (H)
Dimension of works pace (mm) 1260(W1)*780(D1) *1100 (H1) 1560(W1)*780(D1) *1100 (H1)
Panel material 20+6mm thick butterfly ceramics
Material of internal lining board 5mm thick ceramic fiber board
Diversion structure Lower air return
Control system Button control panel (LCD panel)
PH value control The medium is alkaline water solution; manual monitoring, and manual control through acid pump and alkali pump.
Input power Three-phase five-wire 380V/50A
Current for air fan Not over 2.8A(380V or 220V can be directly connected)
Maximum load of socket 12 KW(total of 4 sockets)
Water tap 1 set (remote control valve + water nozzle) No 1 set (remote control valve + water nozzle) No
Water discharge way Magnetic chemical pump strong discharge
Using environment For non-explosion indoor use, within 0-40 degrees Celsius.
Applicable fields Inorganic chemistry experiment; Food, medicine, electronics, environment, metallurgy, mining, etc.
Ways of Purification Spray sodium hydroxide solution, no less than 8 cubic meters/hour Spray sodium hydroxide solution.no less than 12 cubic meters/ hour
Ways of surface air speed control Manual control (through the electric air valve to adjust the exhaust air volume or adjust the height of the moving door)
Average surface air speed 0.6-0.8 m/s Exhaust air volume: 1420-1890m3/h (when door height h =500mm) 0.6-0.8 m/s Exhaust air volume: 1760-2340m3/h (when door height h =500mm)
Speed deviation of surface air Not higher than 10%
The average intensity of illumination Not less than 700 Lux; Standard white and uv-free yellow LED lamps; The illumination is adjustable.
Noise Within 55 decibels
Flow display White smoke can pass through the exhaust outlet, no overflow.
Safety inspection No spikes, edges; Charged body and the exposed metal resistance is greater than 2 mQ; Under 1500V voltage, no breakdown or flashover occurred for 1min test.
Resistance of exhaust cabinet Less than 160 pa
Power consumption Less than 1.0kw/h (excluding power consumption of fans and external instruments) Less than 1.2kw/h (excluding power consumption of fans and external instruments)
Water consumption Less than 3.2L/ h Less than 4.0L/ h
Performance of wind compensation With a unique wind compensation structure, the volume of the wind will not cause turbulence in exhaust cabinet and will not directly blow to the staff (need to connect to the air compensation system of the laboratory)
Air volume regulating valve 315mm diameter flanged type anti-corrosion electric air flow regulating valve (electric contact actuator)
 
Common Applications


Ductless fume hoods are used in various fields. Some of the most common applications are the following:

  • Life Sciences
  • Forensics, Fingerprinting and DNA
  • Educational Purposes
  • Clinics and Hospitals
  • Dental Laboratory
  • Cleanrooms
  • 3D Printing
  • Archaeology
  • Glass Manufacturing
  • Mycology
  • Soldering
  • Pharmaceutical
  • Art Restoration
  • Production of Glues, Paints, and Solvents
Detailed Photos

Acid and Alkali Resistant Laboratory Chemical Ductless Fume Hood
Acid and Alkali Resistant Laboratory Chemical Ductless Fume Hood
Acid and Alkali Resistant Laboratory Chemical Ductless Fume Hood

Application Cases


In choosing a ductless fume hood, you have to consider the following factors:

  • How do you intend to use it? Some ductless fume hoods are designed for light-duty applications or to process specific gases. Other units are built for heavy-duty processes and chemical filtration.
  • Are you working with chemicals that can be filtered with the fume hood's available carbon filters? Apparently, some chemicals or substances can't be safely or effectively sifted if you're only using a ductless fume hood.
  • Is your working place sufficient enough to run ductless fume hoods? Using the ductless fume hood to process air consumes a lot of energy, so you have to make sure that you can afford to manage the large energy consumption and running costs.

Acid and Alkali Resistant Laboratory Chemical Ductless Fume Hood
Acid and Alkali Resistant Laboratory Chemical Ductless Fume Hood

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Chengdu Ample Import And Export Co., Ltd.
Location T2-715, Landmark Plaza, High-Tech Zone, Chengdu, China
Contact Person Mike Ma

Request A Quote

Please check your email address.
Your message must be at least 20 characters.