Energy-Saving Explosion Proof Chemical Fume Hood for Hospital

Price Negotiable
Price: Negotiable
MOQ: Negotiable
Delivery Time: Negotiable
Product Description

Product Description

Company Info.

Customer Question & Answer
Ask something for more details

  • Overview
  • Product Description
  • Product Parameters
  • Installation Instructions
  • Detailed Photos
  • Usage Attention
  • FAQ
Overview

Basic Info.

Model NO.
WJ-1500A
Customized
Customized
Condition
New
Product Name
Benchtop Fume Hood
Worktop
20+6 mm Ceramic
Liner Material
Ceramic Fiber Board
Input Power
380V/50A
Face Velocity
0.4-0.6 M/S
Application
Environment/Institute/Biology Lab/Chemical Lab
Transport Package
Standard Export Wooden Case Packing
Specification
1500*1205*2400 MM
Trademark
Ample
Origin
Chengdu, China
HS Code
8414809090
Production Capacity
200 Set/Month

Product Description

 
Product Description

A laboratory fume hood is a ventilated enclosure where hazardous materials can be    handled safely. The purpose of the hood is to contain contaminants and prevent their  escape into the laboratory. This is accomplished by drawing (by air flow) contaminants within the hood's work area away from the user thereby preventing and minimizing inhalation and contact with hazardous materials.

To create airflow into the hood, an exhaust blower "pulls" air from the laboratory room into and through the hood and exhaust system . A baffle, airfoil, and other aerodynamically designed components control the patterns of air moving into and through the hood.

Fume Hoods must be located away from heavy traffic aisles and doorways so that persons  exiting the lab do not have to pass in front of the fume hood. The potentially dangerous portion of an experiment is usually conducted in a fume hood. Many lab fires and explosions originate in fume hood and a fume hood located adjacent to a path of egress could trap someone in the lab.

There must be two exits from rooms where new fume hoods are to be installed. If this is not feasible, the fume hood must be situated on the side of the room furthest from the   door. A fire or chemical hazard, both of which often start in a fume hood, can render an exit impassible. For this reason, all labs with fume hoods are required to maintain two unblocked routes of egress.

Product Parameters
 
                Model Specification  WJ-1500AWJ-1500BWJ-1800AWJ-1800B
External dimensions of equipment(mm)1500(W)*1205 (D) *2400 (H)1800(W)*1205 (D) *2400 (H)
Dimension of works pace (mm)1260(W1)*780(D1) *1100 (H1)1560(W1)*780(D1) *1100 (H1)
Panel material20+6mm thick butterfly ceramics
Material of internal lining board5mm thick ceramic fiber board
Diversion structureLower air return
Control systemButton control panel (LCD panel)
PH value controlThe medium is alkaline water solution; manual monitoring, and manual control through acid pump and alkali pump.
Input powerThree-phase five-wire 380V/50A
Current for air fanNot over 2.8A(380V or 220V can be directly connected)
Maximum load of socket12 KW(total of 4 sockets)
Water tap1 set (remote control valve + water nozzle)No1 set (remote control valve + water nozzle)No
Water discharge wayMagnetic chemical pump strong discharge
Using environmentFor non-explosion indoor use, within 0-40 degrees Celsius.
Applicable fieldsInorganic chemistry experiment; Food, medicine, electronics, environment, metallurgy, mining, etc.
Ways of PurificationSpray sodium hydroxide solution, no less than 8 cubic meters/hourSpray sodium hydroxide solution.no less than 12 cubic meters/ hour
Ways of surface air speed controlManual control (through the electric air valve to adjust the exhaust air volume or adjust the height of the moving door)
Average surface air speed0.6-0.8 m/s Exhaust air volume: 1420-1890m3/h (when door height h =500mm)0.6-0.8 m/s Exhaust air volume: 1760-2340m3/h (when door height h =500mm)
Speed deviation of surface airNot higher than 10%
The average intensity of illuminationNot less than 700 Lux; Standard white and uv-free yellow LED lamps; The illumination is adjustable.
NoiseWithin 55 decibels
Flow displayWhite smoke can pass through the exhaust outlet, no overflow.
Safety inspectionNo spikes, edges; Charged body and the exposed metal resistance is greater than 2 mQ; Under 1500V voltage, no breakdown or flashover occurred for 1min test.
Resistance of exhaust cabinetLess than 160 pa
Power consumptionLess than 1.0kw/h (excluding power consumption of fans and external instruments)Less than 1.2kw/h (excluding power consumption of fans and external instruments)
Water consumptionLess than 3.2L/ hLess than 4.0L/ h
Performance of wind compensationWith a unique wind compensation structure, the volume of the wind will not cause turbulence in exhaust cabinet and will not directly blow to the staff (need to connect to the air compensation system of the laboratory)
Air volume regulating valve315mm diameter flanged type anti-corrosion electric air flow regulating valve (electric contact actuator)
 
Installation Instructions

Fume hoods should be located within the laboratory to avoid cross currents at the fume hood face due to heating cooling, or ventilation supply or exhaust diffusers.Cross currents outside a hood can nullify or divert air flow onto a hood, negatively affecting its capture ability.

•Sufficient makeup air must be available within the laboratory to permit fume hoods to operate at their specified face velocities. A fume hood exhausts a substantial amount of air. Therefore, additional makeup air must be brought onto the room to maintain a proper air balance.

• Windows in labs that have fume hoods must be fixed closed. Breezes coming in through open lab windows can adversely affect the proper functioning of the hood. Turbulence caused by these wind currents can easily bring the contaminated air inside the hood back into the laboratory.

•Safety devices such as deluge showers, eye wash stations, fire extinguishers, and fire blankets should be located convenient to the fume hood operating personnel.

•Fume hoods shall not have an on/off control accessible in the laboratory, unless the lab has an alternate exhaust ventilation system or the exhaust is being filtered through a charcoal or HEPA filter. Fume hoods are an integral part of the entire laboratory's air balancing system which must be maintained. Labs must be maintained under positive pressure and when a fume hood is turned off the lab can develop positive pressure.

Detailed Photos
       
Energy-Saving Explosion Proof Chemical Fume Hood for Hospital
Energy-Saving Explosion Proof Chemical Fume Hood for Hospital
 
Energy-Saving Explosion Proof Chemical Fume Hood for Hospital
Energy-Saving Explosion Proof Chemical Fume Hood for Hospital

Usage Attention

Close The Sash
When an employee is not working inside the hood, the sash should remain closed.

Avoid Storing Chemicals In The Hood
Employees should never store any chemicals inside the hood when it is not in use. Chemicals should instead be stored in industrial furniture cabinets equipped to hold hazardous chemicals. However, large equipment can be stored in the hood as long as it is on top of blocks to allow air flow under the equipment.

Report Any Problems
Promptly report any issues you have experienced with the fume hood to a supervisor. It is important that a supervisor takes this fume hood out of service until it can be repaired to ensure the safety of employees.

FAQ

What should do if accident accurs?

No one likes to think that an accident may occur. However, if it does, it is always better to be prepared and know what the proper response looks like.

The most important step to take in the immediate aftermath of a fume hood accident is its response. Take any and all actions to safeguard people working in the lab first and foremost. That may include putting out any fires, containing spills, evacuating the area, attending to the injured and contacting emergency services.

After the accident, an investigation must immediately begin. This will prevent important data from being lost and witness forgetting important details. By determining whether safety procedures were followed and whether equipment worked as it should have, new protocols can be put into place to prevent similar future accidents.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Chengdu Ample Import And Export Co., Ltd.
Location T2-715, Landmark Plaza, High-Tech Zone, Chengdu, China
Contact Person Mike Ma

Request A Quote

Please check your email address.
Your message must be at least 20 characters.