Acid & Alkali Resistant Heat Resistant Chemical Explosion Proof Fume Cupboard for Laboratory

Price Negotiable
Price: Negotiable
MOQ: Negotiable
Delivery Time: Negotiable
Product Description

Product Description

Company Info.

Customer Question & Answer
Ask something for more details

  • Overview
  • Product Description
  • Product Parameters
  • More About the Fume Hood
  • Detailed Photos
  • Fume Hood Maintenance
  • FAQ
Overview

Basic Info.

Model NO.
WJ-1800A
Customized
Customized
Condition
New
Product Name
Fume Cupboard
Worktop Material
20+6 mm Ceramic
Liner Material
Ceramic Fiber Board
Input Power
380V/50A
Face Velocity
0.4-0.6 M/S
Application
Environment/Institute/Biology Lab/Chemical Lab
Transport Package
Standard Export Wooden Case Packing
Specification
1500*1205*2400 MM
Trademark
Ample
Origin
Chengdu, China
HS Code
8414809090
Production Capacity
200 Set/Month

Product Description

Product Description

For many years, fume hood manufacturers, laboratory safety standards1and safety professionals have maintained that a face velocity of about 100 fpm was generally required for adequate fume containment and thus safe fume hood use.

More recently, many experienced and renowned fume hood safety professionals have stated that having the recommended fume hood face velocity is no guarantee that a given fume hood will provide adequate fume containment and user safety. And, newer editions of laboratory safety standards contain extensive warnings against using face velocity as the sole criteria for safe fume hood. Individuals who have wide-ranging experience in fume hood containment testing, especially with the ASHRAE 110 tracer gas test, will frequently cite their own test results as evidence against equating adequate face velocity with adequate fume containment.

Product Parameters
 
                Model Specification  WJ-1500AWJ-1500BWJ-1800AWJ-1800B
External dimensions of equipment(mm)1500(W)*1205 (D) *2400 (H)1800(W)*1205 (D) *2400 (H)
Dimension of works pace (mm)1260(W1)*780(D1) *1100 (H1)1560(W1)*780(D1) *1100 (H1)
Panel material20+6mm thick butterfly ceramics
Material of internal lining board5mm thick ceramic fiber board
Diversion structureLower air return
Control systemButton control panel (LCD panel)
PH value controlThe medium is alkaline water solution; manual monitoring, and manual control through acid pump and alkali pump.
Input powerThree-phase five-wire 380V/50A
Current for air fanNot over 2.8A(380V or 220V can be directly connected)
Maximum load of socket12 KW(total of 4 sockets)
Water tap1 set (remote control valve + water nozzle)No1 set (remote control valve + water nozzle)No
Water discharge wayMagnetic chemical pump strong discharge
Using environmentFor non-explosion indoor use, within 0-40 degrees Celsius.
Applicable fieldsInorganic chemistry experiment; Food, medicine, electronics, environment, metallurgy, mining, etc.
Ways of PurificationSpray sodium hydroxide solution, no less than 8 cubic meters/hourSpray sodium hydroxide solution.no less than 12 cubic meters/ hour
Ways of surface air speed controlManual control (through the electric air valve to adjust the exhaust air volume or adjust the height of the moving door)
Average surface air speed0.6-0.8 m/s Exhaust air volume: 1420-1890m3/h (when door height h =500mm)0.6-0.8 m/s Exhaust air volume: 1760-2340m3/h (when door height h =500mm)
Speed deviation of surface airNot higher than 10%
The average intensity of illuminationNot less than 700 Lux; Standard white and uv-free yellow LED lamps; The illumination is adjustable.
NoiseWithin 55 decibels
Flow displayWhite smoke can pass through the exhaust outlet, no overflow.
Safety inspectionNo spikes, edges; Charged body and the exposed metal resistance is greater than 2 mQ; Under 1500V voltage, no breakdown or flashover occurred for 1min test.
Resistance of exhaust cabinetLess than 160 pa
Power consumptionLess than 1.0kw/h (excluding power consumption of fans and external instruments)Less than 1.2kw/h (excluding power consumption of fans and external instruments)
Water consumptionLess than 3.2L/ hLess than 4.0L/ h
Performance of wind compensationWith a unique wind compensation structure, the volume of the wind will not cause turbulence in exhaust cabinet and will not directly blow to the staff (need to connect to the air compensation system of the laboratory)
Air volume regulating valve315mm diameter flanged type anti-corrosion electric air flow regulating valve (electric contact actuator)
 
More About the Fume Hood

Face velocity is the average amount of air that is pulled through the face of a hood. If these velocities are too low then chemical fumes can escape the hood and go back into the lab. If the velocities are too high, energy costs will be high as you exhaust large amounts of conditioned air from the room. In other words, if too much air is being pulled into the machine (high volumetric flow) it becomes extremely inefficient. If too little air is being pulled into the machine (low volumetric flow), then it can be dangerous for those around the equipment. Airspeed is everything when discussing face velocity. Today we are going to discuss fume hood face velocity requirements, so you can keep your equipment safe and efficient.

Average velocity is calculated by dividing the sash opening into an imaginary grid pattern. Each square of this grid should be approximately 1ftsq. Then take air measurements (velocity readings) at the center point in each of these imaginary squares. You can do this using a velometer, anemometer or similar device. Each one of these readings should be for approximately 10 seconds (the longer the better). Record the reading in a notepad and repeat until you have measured from all squares. Once complete analyze the measurements and look for outliers.

Detailed Photos
             
Acid & Alkali Resistant Heat Resistant Chemical Explosion Proof Fume Cupboard for Laboratory
Acid & Alkali Resistant Heat Resistant Chemical Explosion Proof Fume Cupboard for Laboratory
 
Acid & Alkali Resistant Heat Resistant Chemical Explosion Proof Fume Cupboard for Laboratory
Acid & Alkali Resistant Heat Resistant Chemical Explosion Proof Fume Cupboard for Laboratory

Fume Hood Maintenance

Hoods should be evaluated by the user before each use to ensure adequate face velocities and the absence of excessive turbulence.

• In case of exhaust system failure while using a hood, shut off all services and accessories and lower the sash completely. Leave the area immediately.

 Fume  hoods should  be certified, at  least annually, to ensure they are operating safely. Typical tests include face velocity measurements, smoke tests and tracer gas containment. Tracer gas containment tests are especially crucial, as studies  have shown that face velocity is not a good predictor of fume hood leakage.

• Laboratory fume hoods are one of the most important used and abused hazard control devices. We should understand that the combined use of safety glasses, protective gloves, laboratory smocks, good safety practices, and laboratory fume hoods are very important elements in protecting us from a potentially hazardous exposure.

 Laboratory fume hoods only protect users when they are used properly and are working correctly. A fume hood is designed to protect the user and room occupants from  exposure to vapors,  aerosols, toxic  materials,  odorous,  and  other  harmful substances. A secondary purpose is to serve as a protective shield when working with potentially explosive or highly reactive materials. This is accomplished by lowering the hood sash.
FAQ

6 Questions to Ask When Buying a Fume Hood:

-Which chemicals will you use within the hood?

-Is a ducted or ductless hood best suited to your needs and available space?

-Where will you place the fume hood in the lab? Consider workflows, access to external exhaust systems, and competing air patterns.

-What size fume hood will best suit your needs? Be sure to consider what (if any) equipment will be enclosed in the hood.

-Are any service fixtures or accessories such as airflow monitors, electrical outlets, water, or gas fixtures required?

-Are base cabinets for acid, solvent, or non-chemical storage required?

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Chengdu Ample Import And Export Co., Ltd.
Location T2-715, Landmark Plaza, High-Tech Zone, Chengdu, China
Contact Person Mike Ma

Request A Quote

Please check your email address.
Your message must be at least 20 characters.