Mutations Detection Saliva Self Test Kit SARS-CoV-2 Individual Ag Rapid Test Device
SARS-CoV-2 Antigen Saliva Rapid Test Kit Self-test For Home Use (Immunochromatography)
Intended Use
- Qualitative detection of SARS-CoV-2 antigen in human saliva samples from novel coronavirus suspected person with symptoms within 9 days from onset.
- Positive result of the antigen test can be used for early triage and rapid management of suspected populations.
- Negative results do not rule out SARS-CoV-2 infection and should not be used as the sole basis for treatment or patient management decisions.
- Nucleic acid detection should be carried out for suspected population whose antigen test result is positive or negative.
Product Details
| Item | Value |
| Model Number | LX-401602 |
| Package | 1 Test |
| Warranty | 18 Months |
| Safty Standard | ISO13485 |
| Sample Type | Saliva |
| Sample volume | 3 Full drops |
| Test Speed | Within 15 minutes |
| Use | For Self-test At Home |
Product Feature
- Fast: Result in 15 minutes
- Simple: Easy to use, no extra operation
- Reliable: High accuracy and safety
- Variety: Detection of mutations
Test Principle
This kit is an immunochromatography assay. According to the gold immunochromatographic test principle, double antibody sandwich method was used to detect SARS-CoV-2 nucleocapsid antigen in the samples. Whether the sample contains antigen or not, the gold monoclonal antibody will bind to the enveloped antibody at the quality control line, form a compound and condense into a red band.
Main Components
- 1 Test Cassette
- 1 Saliva Collectors With Collection Tube
- 1 Sample Extraction Buffer
- 1 Package Insert
Use Step
- Open the cap of the collection tube and istall saliva collector.
- Put the collection tube with saliva collector close to lips and let the saliva flow into the collection tube. Tje volum of saliva needs to be half of 0.5 scal mark(0.25).
- Screw the sample extraction buffer carefully.
- Add all sample extration buffer to the collection tube. Discard the saliva collector, tighten the cap onto the specimen collection tube.
- Shake the specimen collection tube at least three time vigorously to mix the saliva and the extraction buffer. Squeeze bottom of the collection tube ensure the saliva is thoroughly mixed.
- Add 3 full drops of the solution to the sample well(S). Read the result at 15 minutes. Do not interpret the result after 20 minutes.
Result Interpretation
-
POSITIVE: Two (2) distinct colored lines appear. One line should be in the control region (C) and the other line should be in the test region (T).
-
NEGATIVE: One (1) colored line appears in the control region(C). No apparent colored line appears in the test region (T). The negative result does not indicate the absence of analytes in the sample, it only indicates the level of tested analytes in the sample is less than the minimum detection limit.
-
INVALID: No colored lines appear, or control line fails to appear, indicating that the operator error or reagent failure. Verify the test procedure and repeat the test with a new testing device.
Virus Sources
| Global high frequency mutation | Alpha / B.1.1.7(U.K.) | Beta I B.1.351(South Africa) |
| Gemma I P.1(Brazil) | Kappa I B.1.617.1(India) | Delta I B.1.617.2(India) |
| C.37,ect | Alpha I B.1.17(U.K.) | B.1.36.16.etc |
| A.2.5,etc | A.23.1 | Alpha I B.1.17(U.K.) |
| B.1.1.33.etc | C.1.1.etc. |
Advantage
- One-step Operation without extra step
- Individual Package, easy to carry
- Saliva specimen, easy to collect
- Unique design, simple and convenient