3 Min Whole Blood Hemoglobin A1c Testing Equipment

Price Negotiable
Price: Negotiation
MOQ: 1
Delivery Time: 10 work day
Brand: LABNOVATION
Product Description

HbA1c Test Analyzer Hemoglobin Detection Analysis LD-100 Poct HbA1c Fully Automatic Testing Analyzer

Intended Use

The instrument is LD-100(POCT) One-Step HbA1c Analyzer, it's intended for the percent determination of hemoglobin A1c (HbA1c) in human
whole blood. LD-100 HbAc Analyzer is composed of the systems of sample cup mixing, colorimetric detection and system control, result display which can fast testing Hemoglobin with less time. Because the LD-100 HbA1c Analyzer is small and light so it 's very protable and suitable for the detection of HbA1c in medical units at all levels.

Specifications

Model LD-100
Sample Type Whole blood
Sample Volume 4ul
Testing Time Within 3 minutes
Data storage 7000
Power connection Detachable power supply cord
System Compose Sample cup mixing, Colorimetric detection And System control, Result display
Device category: Fixed
Measurement Range HbA1c 4.0~15%(NGSP Unit)
eAG 68-385mg/dl(mmol/l)
Operating Condition Temperature:15~35℃
Humidity:15~80%R.H
Storage Condition Analyzer:10-60℃; Test kit: 2~8℃
Voltage 12VDC-3.33A
Analytical wave-length 510nm and 580nm.
Certification NGSP, IFCC

 

 

PRINCIPLE

  • Uses the (borate affinity) fluorescent immunoturbidimetry
  • Push a mixture containing a fluorescent borate conjugate into an integrated test cup and mix to dissolve sufficiently.
  • The blood samples in the sample collector are then pushed into the buffer and mixed to release the hemoglobin from the red blood cells.
  • The total concentration of hemoglobin depends on the initial reduced fluorescence signal.
  • Fluorescent borate conjugates bind to glycosylated hemoglobin, and glycosylated hemoglobin is determined by detecting the decrease of fluorescent active ingredients.
  • The percentage of glycosylated hemoglobin in total hemoglobin can be determined.

Feature

  • One-Step Testing,Fully Automatic System 
  • Protable and convenient, Testing Anytime , Anywhere
  • Fast test speed and High Accuracy within 3 min
  • Battery Integrated
  • Cv<3%, Excellent Correlation With HPLC
  • RFID For Batch Management
  • Color touch screen just need to clik the screen and easy to read

Reliable

IFCC calibrator Normal Abnormal Normal Abnormal
Mean HbA1c% 5.4 9.6 5.3 9.2
CV (%) 2.5% 1.9% 2.4% 1.8%

 

Use Step

  • Place cartridge in analyzer
  • Push bead into reagents
  • Insert sample into cartridge

 

Performance Parameters

  • Accuracy: Is tested with the reference material as samples, and the relative deviation of the determination results of the analyzer should be within the range of ±8%.
  • Precision:Samples with a concentration of 4.0%-6.5% are detected, sample coefficient of variation (CV) of the test results is not more than 3%.
  • Linearity:In the range of 4%-16% of HbA1c, the linear correlation coefficientrof the test results should be no less than 0.9900.
  • Stability:Within 8 hours after the instrument is turned on and stable, the relative deviation of the test results is not more than ±3%.
  • Functions of the analyzer:The function of report output in English;  Abnormal alarm function.

 

Certificated

 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Labnovation Technologies, Inc.
Location 101 and 5th Floor, Building 1, No. 68,18th Road, Guangming Hi-Tech Park, Tangjia Community, Fenghuang Street, Guangming District, Shenzhen 518107 ,China
Contact Person Aimee li

Request A Quote

Please check your email address.
Your message must be at least 20 characters.