Labnovation Technologies, Inc.
                                                                                                           
Verified Supplier
25 Years
Since 2001
Menu
Home & Garden Pet Products Pet Health Care & Supplements

15 Minutes Fast Saliva Antigen Test Kit Universal Ag Rapid Test Device

Price Negotiable
Price: Negotiation
MOQ: 10000 Pieces
Delivery Time: 5-7 work day
Brand: LABNOVATION
Product Description

Rapid Test Kit Antigen Saliva Rapid Test Kit SARS-CoV-2 Antigen Saliva Rapid Test Kit High Accuracy Antigen Rapid Test Kit


Intend Use

This rapid test kit is intendedfor the qualitative detection od SARS-CoV-2 antigen in human saliva samples from novel coronavirus suspected person with symptoms within 9 days from onset. The result can be used  for early triage and rapid management of suspected populations, but it cannot be used as diagnosis basis of SARS-CoV-2 infection. The negative results do not rule out SARS-CoV-2 infection and should not be used as the sole basis for treatment or patient management decisions. Further nucleic acid detection should be carried out for suspected population whose antigen test result is positive or negative. 
Product Details

Item Value
Brand Labnovation
Model Number LX-401603
Type 20 Tests / Kit
Warranty 24 Months
Quality Certification CE, MSDS
Safty Standard ISO13485,ISO9001
Sample Type Saliva
Sample volume 3 Full drops
Test Speed Within 15 minutes
specificity 99.00%
sensitivity 94.29%

 
Product  Feature

  • Fast: Result easy to read within 15 minutes
  • Simple: One step operation process
  • Reliable: Individual package buffer, safety and reliability
  • Accurate: High accuracy, specificity and sensitivity

     
    Main Components
  • Test Cassettes
  • Saliva Collectors With Collection Tubes 
  • Sample Extraction Buffer
  • Tube stand
  • Package Insert


 
Use Step

  • Open the cap of the collection tube and istall saliva collector.
  • Put the collection tube with saliva collector close to lips and let the saliva flow into the collection tube. Tje volum of saliva needs to be half of 0.5 scal mark(0.25).
  • Screw the sample extraction buffer carefully.

  • Add all sample extration buffer to the collection tube. Discard the saliva collector, tighten the cap onto the specimen collection tube.
  • Shake the specimen collection tube at least three time vigorously to mix the saliva and the extraction buffer. Squeeze bottom of the collection tube ensure the saliva is thoroughly mixed.
  • Add 3 full drops of the solution to the sample well(S). Read the result at 15 minutes. Do not interpret the result after 20 minutes.

 
Result Interpretation

  • POSITIVE: Two (2) distinct colored lines appear. One line should be in the control region (C) and the other line should be in the test region (T).

  • NEGATIVE: One (1) colored line appears in the control region(C). No apparent colored line appears in the test region (T). The negative result does not indicate the absence of analytes in the sample, it only indicates the level of tested analytes in the sample is less than the minimum detection limit.

  • INVALID: No colored lines appear, or control line fails to appear, indicating that the operator error or reagent failure. Verify the test procedure and repeat the test with a new testing device.

 
 
Virus Sources

Global high frequency mutation Alpha / B.1.1.7(U.K.) Beta I B.1.351(South Africa)
Gemma I P.1(Brazil) Kappa I B.1.617.1(India) Delta I B.1.617.2(India)
C.37,ect Alpha I B.1.17(U.K.) B.1.36.16.etc
A.2.5,etc A.23.1 Alpha I B.1.17(U.K.)
B.1.1.33.etc C.1.1.etc. etc.

 

Other Information

  • This kit is a qualitative detection, which cannot determine the exact content of antigen.
  • The test cassette should be used as soon as possible after removal from aluminum foil bags. Avoid exposure to air for too long and affecting test results due to dampness.
  • Waste should be treated in accordance with infectious substances and should be discarded properly.
  • If the saliva is not well mixed in the sample extraction tube, false negative results may occur.
  • Keep away from children. Any child under age 13 shouldn’t perform the test without parental guidance, or professional aid. 

Certificate

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Labnovation Technologies, Inc.
Location 101 and 5th Floor, Building 1, No. 68,18th Road, Guangming Hi-Tech Park, Tangjia Community, Fenghuang Street, Guangming District, Shenzhen 518107 ,China
Contact Person Aimee li

Request A Quote

Please check your email address.
Your message must be at least 20 characters.