Rapid Test Kit SARS-CoV-2 Antigen Saliva Rapid Test Single Pack 1 Test Kit For Professional Use


Intend Use
This rapid test kit is intended for the qualitative detection of SARS-CoV-2 antigen in human saliva samples from novel coronavirus suspected person with symptoms within 9 days from onset. Positive result of the antigen test can be used for early triage and rapid management of suspected populations, but it cannot be used as diagnosis basis of SARS-CoV-2 infection. Negative results do not rule out SARS-CoV-2 infection and should not be used as the sole basis for treatment or patient management decisions. Further nucleic acid detection should be carried out for suspected population whose antigen test result is positive or negative.

Product Details

Item Value
Brand Labnovation
Model Number LX-401601
Type 1 Test / Kit
Warranty 24 Months
Quality Certification CE, MSDS
Storage Temperature 2℃-30℃
Sample Type Saliva
Sample volume 3 Full drops
Test Speed Within 15 minutes
sensitivity 94.29%
specificity 99.00%
Total coincidence rate 98.02%
Quality ISO13485, ISO9001

 
Product  Feature

  • Fast results as soon as 15 minutes
  • Facilitates patient treatment decisions quickly
  • Simple, time-saving procedure
  • All necessary reagents provided and no equipment need
  • High sensitivity and specificity

 

  • Main Components
  •  1 Test Cassette
  •  1 Saliva Collector 
  •  1 Collection Tube 
  •  1 Sample Extraction Buffer (Single does)
  •  1 Package Insert

 
Use Step

  • Open the cap of the collection tube and istall saliva collector.
  • Put the collection tube with saliva collector close to lips and let the saliva flow into the collection tube. Tje volum of saliva needs to be half of 0.5 scal mark(0.25).
  • Screw the sample extraction buffer carefully.

  • Add all sample extration buffer to the collection tube. Discard the saliva collector, tighten the cap onto the specimen collection tube.
  • Shake the specimen collection tube at least three time vigorously to mix the saliva and the extraction buffer. Squeeze bottom of the collection tube ensure the saliva is thoroughly mixed.
  • Add 3 full drops of the solution to the sample well(S). Read the result at 15 minutes. Do not interpret the result after 20 minutes.

 
Result Interpretation

  • POSITIVE: Two (2) distinct colored lines appear. One line should be in the control region (C) and the other line should be in the test region (T).

  • NEGATIVE: One (1) colored line appears in the control region(C). No apparent colored line appears in the test region (T). The negative result does not indicate the absence of analytes in the sample, it only indicates the level of tested analytes in the sample is less than the minimum detection limit.

  • INVALID: No colored lines appear, or control line fails to appear, indicating that the operator error or reagent failure. Verify the test procedure and repeat the test with a new testing device.

 
 
Virus Sources

Global high frequency mutation Alpha / B.1.1.7(U.K.) Beta I B.1.351(South Africa)
Gemma I P.1(Brazil) Kappa I B.1.617.1(India) Delta I B.1.617.2(India)
C.37,ect Alpha I B.1.17(U.K.) B.1.36.16.etc
A.2.5,etc A.23.1 Alpha I B.1.17(U.K.)
B.1.1.33.etc C.1.1.etc. etc.

 

PRECAUTION

  • Waste should be treated in accordance with infectious substances and should be discarded properly.
  • Incorrect operation may affect the accuracy of the results, such as sample extraction reagent insufficient or excessive, insufficient sample mixing, insufficient amount, inaccurate detection time, etc.
  • Components in different batch should not be mixed; Viral Transport Media (VTM) may affect the test result; extracted specimens for PCR tests cannot be used for the test.
  • If the saliva is not well mixed in the sample extraction tube, false negative results may occur.
  • Keep away from children. Any child under age 13 shouldn’t perform the test without parental guidance, or professional aid.


Certificate

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Labnovation Technologies, Inc.
Location 101 and 5th Floor, Building 1, No. 68,18th Road, Guangming Hi-Tech Park, Tangjia Community, Fenghuang Street, Guangming District, Shenzhen 518107 ,China
Contact Person Aimee li

Request A Quote

Please check your email address.
Your message must be at least 20 characters.