CoV-2 Persnoal Saliva RTK Home Test Kit Single Pack Self Test
Rapid Test Kit Antigen Saliva Rapid Test CoV-2 Antigen Saliva Rapid Testing Single Pack Self Test Kit
Intend Use
This rapid test kit is intended for the qualitative detection of SARS-CoV-2 antigen in human saliva sample from novel coronavirus suspected person with symptoms within 9 days from onset. The test result can be used for early triage and rapid management of suspected populations, but it cannot be used as diagnosis basis of SARS-CoV-2 infection. For the further nucleic acid detection should be carried out for suspected population whose antigen test result is positive or negative.
Product Details
| Item | Value |
| Model Number | LX-401602 |
| Type | 1 Test / BoX |
| Warranty | 18 Months |
| Power Source | Instruction Manual |
| Safty Standard | ISO13485 |
| After-sale Service | Online technical support |
| Sample volume | 3 Full drops |
| Total coincidence rate | 98.02% |
| Sensitivity | 94.29% |
| Specificity | 99.00% |
Product Feature
- One-step Operation
- High Accuracy, Specificity and Sensitivity
- Individual Sample Buffer
- Detection of mutations
- Self-test At Home Use
- Easy to collect specimen
Main Components
- 1 Test Cassette
- 1 Saliva Collectors With Collection Tube
- 1 Sample Extraction Buffer
- 1 Package Insert
SAMPLE COLLECTION
30 minutes before sampling, please do not eat, smoke, drinking alcohol or drinks.
SAMPLE PRESERVATION
After the samples of human saliva are collected, the saliva should be processed as soon as possible and tested within 1 hour. If it cannot be tested immediately, it can be stored at 2-8℃ for 4 hours and long-term storage is not recommended.
Use Step
- Open the cap of the collection tube and istall saliva collector.
- Put the collection tube with saliva collector close to lips and let the saliva flow into the collection tube. Tje volum of saliva needs to be half of 0.5 scal mark(0.25).
- Screw the sample extraction buffer carefully.
- Add all sample extration buffer to the collection tube. Discard the saliva collector, tighten the cap onto the specimen collection tube.
- Shake the specimen collection tube at least three time vigorously to mix the saliva and the extraction buffer. Squeeze bottom of the collection tube ensure the saliva is thoroughly mixed.
- Add 3 full drops of the solution to the sample well(S). Read the result at 15 minutes. Do not interpret the result after 20 minutes.
Result Interpretation
-
POSITIVE: Two (2) distinct colored lines appear. One line should be in the control region (C) and the other line should be in the test region (T).
-
NEGATIVE: One (1) colored line appears in the control region(C). No apparent colored line appears in the test region (T). The negative result does not indicate the absence of analytes in the sample, it only indicates the level of tested analytes in the sample is less than the minimum detection limit.
-
INVALID: No colored lines appear, or control line fails to appear, indicating that the operator error or reagent failure. Verify the test procedure and repeat the test with a new testing device.
Virus Sources
| Global high frequency mutation | Alpha / B.1.1.7(U.K.) | Beta I B.1.351(South Africa) |
| Gemma I P.1(Brazil) | Kappa I B.1.617.1(India) | Delta I B.1.617.2(India) |
| C.37,ect | Alpha I B.1.17(U.K.) | B.1.36.16.etc |
| A.2.5,etc | A.23.1 | Alpha I B.1.17(U.K.) |
| B.1.1.33.etc | C.1.1.etc. | etc. |
Advantage
- Sensitivity and specificity are higher
- Save Time and simple operation
- No professional technicians and equipment are required
- Test can be completed in 15 minutes
- Home use
- Persnoal test
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.