Labnovation Technologies, Inc.
                                                                                                           
Verified Supplier
25 Years
Since 2001
Menu
Chemicals Chemical Reagents

Hematology Reagent For Sysmex Xt-2000i, Xt-1800i Analyzers Best Performance Hematology Analyzer Reagents

Price Negotiable
Price: US$8-12/Pieces
MOQ: 500 Pieces
Delivery Time: 10 work day
Brand: LABNOVATION
Product Description

Hematology Reagent For Sysmex Xt-2000i, Xt-1800i Analyzers Best Performance Hematology Analyzer Reagents

 

Intended Use

To be used for blood cell counting, sizing, and WBC differentiation, hemoglobin determination on Sysmex XT-2000i, XT-1800i hematology analyzers. This product is for In Vitro Diagnostic Use only.

Precautions
  • Re-calibration is recommended when changing the origin of the reagents.
  • It is not recommended using different brands of solutions together on one unit of analyzer.
  • Do not ingest. Avoid contact with skin and eyes.
  • Skin contact: Flush with plenty of water.
  • Eyes contact: Flush with plenty of water. Obtain immediate medical attention.
  • This kit is for professionals and in vitro diagnostic use only.
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

Specification

20-10-020 DILUENT-ST 20 L
23-30-FFD 4DL-LYSER 5 L
23-30-FFS-8-01 4DS-LYSER 1 L
23-30-SLS-A05 SLS-LYSER 500ML×3
23-30-FBA-A5 FB-LYSER 5 L
21-CL-50 CELL-CLEANER 50 ML

 

KIT COMPOSITION

DILUENT-ST NaCl≤9.4%, Buffer≤1.6%, Anti-Microbial Agent≤1.0%
4DL-LYSER Non-ionic Surfactant<0.2%
4DS-LYSER

Ethylene glycol>90%, Polymethine dye<0.006%

SLS-LYSER Sodium Lauryl Sulfate<0.2%
FB-LYSER Non-ionic Surfactant<0.5%
CELL-CLEANER Sodium Hypochlorite 5%
 

 Procedures

  • Remove the diluents tubing from the currently used Cellpack.
  • Wipe the tube’s surface with a lent free tissue, and then rinse with distilled water.
  • Loosen and remove the cap on the cubitainers or bottles or sachet, attach the dispenser assembly to the cubintainer or bottle or sachet, then tighten the caps.
  • Connect the other reagents to the analyzer in the same way.
  • Prime the reagents though the instrument completely according to the operator’s manual.
  • Recalibrate the unit if necessary.

Storage

  • Store the product at 5-35℃ in a dust free place with good ventilation. Temperature outside the range may damage the product.
  • The open vial life of the product is 30/60 days. Unused reagents should be discarded after 30/60 days. Do not mix residual with a new carton. 
Advantage
  • One source for all brands of analyzer 
  • Reagents for both 3-parts and 5-parts
  • Ready-to-use final products and bulk OEM reagents
  • ISQ13485:2003 and ISO9001:2008 certified
  • CE marked, FDA cleared
  • Well-established brand used by thousands of lab in 95 countries
  • High quality, high performance and high fidelity of correlations with original brand
 
 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Labnovation Technologies, Inc.
Location 101 and 5th Floor, Building 1, No. 68,18th Road, Guangming Hi-Tech Park, Tangjia Community, Fenghuang Street, Guangming District, Shenzhen 518107 ,China
Contact Person Aimee li

Request A Quote

Please check your email address.
Your message must be at least 20 characters.